  • 3 Cable entry M 20 x 1.5
  • Metal enclosure
  • 3 Contacts
  • 67 mm x 105 mm x 43 mm ( basic component)

Ordering data

Note (Delivery capacity)

Not available!

Product type description

TS 016-12Y

Article number (order number)

101054860

EAN (European Article Number)

4030661002040

Approval - Standards

Certificates

cULus

CCC

EAC

General data

Standards

EN 60947-5-1

Active principle

mechanical

Slide form

Sphere

Enclosure material

Light-alloy diecast, paint finish

Enclosure coating material

painted

Material of the contacts, electrical

Silver

Gross weight

340 g

General data - Features

Number of openers

2

Number of shutters

1

Mechanical data

Actuating element

Plunger

Mechanical life, minimum

5,000,000 Operations

Actuating angle

20 °

Actuating force

23 N

Contact opening

2 x 2.5 mm

Actuating speed, minimum

1 mm/min

Actuating speed, maximum

1 m/s

Note (Actuating speed)

Actuating speed with vertical actuating angle to switch axis

Mechanical data - Connection technique

Terminal Connector

Screw connection

Cable section, maximum

2.5 mm²

Note (Cable section)

All indications about the cable section are including the conductor ferrules.

Wire cross-section

13 AWG

Mechanical data - Dimensions

Length of sensor

43 mm

Width of sensor

67 mm

Height of sensor

116 mm

Diameter of the Plunger

6 mm

Ambient conditions

Degree of protection

IP65 to EN 60529

Ambient temperature, minimum

-30 °C

Ambient temperature, maximum

+90 °C

Ambient conditions - Insulation value

Rated insulation voltage Ui

500 V

Electrical data

Thermal test current

10 A

Utilisation category AC-15

400 VAC

Utilisation category AC-15

4 A

Switching element

NO contact, NC contact

Note (Switching element)

with double break

Switching principle

Creep circuit element

Notes

Note (General)

Actuation from the side of the plunger should be avoided, since this reduces the mechanical life of the position switch.