- NOTICE: Not available!
- 1 Cable entry M 20 x 1.5
- Thermoplastic enclosure
- DC 4-wire
- Double-insulated
- Wiring compartment
- Design 333
Ordering data
Note (Delivery capacity) | Not available! |
Product type description | IFL 15-333-11YNG |
Article number (order number) | 101055048 |
eCl@ss number, Version 9.0 | 27-27-01-01 |
eCl@ss number, Version 11.0 | 27-27-01-01 |
ETIM number, version 6.0 | EC002714 |
ETIM number, version 7.0 | EC002714 |
General data
Standards | IEC/EN 60947-5-2 DIN VDE 0660-208 |
Housing construction form | Block |
Installation conditions (mechanical) | flush |
Enclosure material | Plastic |
Material of the cover | Luran |
Gross weight | 155 g |
General data - Features
Integral System Diagnostics, status | Yes |
Number of cable wires | 4 |
Mechanical data - Switching distances according IEC 60947-5-3
Switch distance | 15 mm |
Mechanical data - Connection technique
Terminal Connector | Screw connection |
Cable section, maximum | 2 x 1.5 mm² |
Mechanical data - Dimensions
Length of sensor | 40 mm |
Width of sensor | 40 mm |
Height of sensor | 112 mm |
Ambient conditions
Degree of protection | IP65 to EN 60529 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +70 °C |
Protection rating | II |
Electrical data
Voltage type | DC (direct current) |
Operating voltage, minimum | 10 V |
Operating voltage, maximum | 60 V |
No-load supply current I0 | 5.5 mA |
Operating current | 400 mA |
Switching element | NO contact and NC contact (antivalent) |
Protection circuit integrated | inductive interference protection Protection against polarity reversal |
Switching frequency, approx. | 100 Hz |
Electrical data - Digital Output
Voltage drop Ud, maximum | 1.5 V |
Current at Voltage drop Ud | 0.4 A |
Versions | n-type |
Status indication
Note (Integral System Diagnostics, status ) | yellow LED |
Notes
Note (General) | By repositioning the switch 5 different actuating directions can be selected. The selected actuating direction can be marked with a sticker. |