- Metal enclosure
- 184 mm x 111 mm x 149 mm (basic component)
- 2 cable entries M 25 x 1.5
- 3 or 4 Contacts
- Actuator heads can be repositioned by 4 x 90°
Ordering data
Product type description | MS 064-13Y |
Article number (order number) | 101056942 |
EAN (European Article Number) | 4030661022635 |
eCl@ss number, Version 9.0 | 27-27-06-01 |
eCl@ss number, Version 11.0 | 27-27-06-01 |
ETIM number, version 6.0 | EC000030 |
ETIM number, version 7.0 | EC000030 |
Approval - Standards
Certificates | cULus CCC EAC |
General data
Standards | EN 60947-5-1 |
Active principle | mechanical |
Slide form | Sphere |
Enclosure material | Grey cast iron, galvanised |
Enclosure coating material | painted |
Material of the contacts, electrical | Silver |
Gross weight | 3,715 g |
General data - Features
Number of openers | 3 |
Number of shutters | 1 |
Safety appraisal - Safety outputs
B10d Normally-closed contact (NC) | 2,000,000 Operations |
Mechanical data
Actuating element | Plunger |
Mechanical life, minimum | 30,000 Operations |
Actuating angle | 20 ° |
Contact opening | 2 x 4 mm |
Actuating speed, minimum | 600 mm/min |
Actuating speed, maximum | 1 m/s |
Note (Actuating speed) | Actuating speed with vertical actuating angle to switch axis |
Mechanical data - Connection technique
Terminal Connector | Screw connection |
Cable section, minimum | 1.5 mm² |
Cable section, maximum | 4 mm² |
Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Wire cross-section | 11 AWG |
Mechanical data - Dimensions
Length of sensor | 149 mm |
Width of sensor | 156 mm |
Height of sensor | 111 mm |
Diameter of the Plunger | 10 mm |
Ambient conditions
Degree of protection | IP65 to EN 60529 |
Ambient temperature, minimum | -30 °C |
Ambient temperature, maximum | +90 °C |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 500 V |
Rated impulse withstand voltage Uimp | 6 kV |
Electrical data
Thermal test current | 25 A |
Utilisation category AC-15 | 400 VAC |
Utilisation category AC-15 | 25 A |
Switching element | NO contact / NC contact |
Note (Switching element) | galvanically separated contact bridges |
Switching principle | Snap switch element |
Switching frequency | 1,000 /h |
Notes
Note (General) | Actuation from the side of the plunger should be avoided, since this reduces the mechanical life of the position switch. |