- 2 cable entries M 20 x 1.5
- Metal enclosure
- 118 mm x 155 mm x 64 mm ( basic component)
- Actuator can be repositioned by 90°
Ordering data
Product type description | MR 461-22Y |
Article number (order number) | 101058853 |
EAN (European Article Number) | 4030661034027 |
eCl@ss number, Version 9.0 | 27-27-06-01 |
eCl@ss number, Version 11.0 | 27-27-06-01 |
ETIM number, version 6.0 | EC000030 |
ETIM number, version 7.0 | EC000030 |
Approval - Standards
Certificates | DNV.GL EAC |
General data
Standards | EN 60947-5-1 |
Active principle | mechanical |
Slide form | Castor |
Enclosure material | Grey cast iron, galvanised |
Enclosure coating material | painted |
Material of the contacts, electrical | Silver |
Roller material | Plastic |
Gross weight | 1,955 g |
General data - Features
Number of openers | 2 |
Number of shutters | 2 |
Safety appraisal - Safety outputs
B10d Normally-closed contact (NC) | 2,000,000 Operations |
Mechanical data
Actuating element | Roller plunger |
Mechanical life, minimum | 5,000,000 Operations |
Actuating angle, from left of switch axis | 30 ° |
Actuating angle, from right of switch axis | 30 ° |
Contact opening | max. 2 x 2.5 mm |
Actuating speed, minimum | 1 mm/min |
Actuating speed, maximum | 0.5 m/s |
Note (Actuating speed) | Actuating speed with vertical actuating angle to switch axis |
Mechanical data - Connection technique
Terminal Connector | Screw connection |
Cable section, minimum | 1.5 mm² |
Cable section, maximum | 2.5 mm² |
Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Wire cross-section | 13 AWG |
Mechanical data - Dimensions
Length of sensor | 64 mm |
Width of sensor | 118 mm |
Height of sensor | 201 mm |
Width of Castor | 6.5 mm |
Diameter of Castor | 25 mm |
Ambient conditions
Degree of protection | IP65 to EN 60529 |
Ambient temperature, minimum | -30 °C |
Ambient temperature, maximum | +90 °C |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 4 kV |
Electrical data
Thermal test current | 16 A |
Utilisation category AC-15 | 230 VAC |
Utilisation category AC-15 | 4 A |
Switching element | NO contact / NC contact |
Note (Switching element) | with double break |
Switching principle | Snap switch element |
Bounce duration, maximum | 5 ms |
Switchover time, maximum | 35 ms |