- Single wire entry with Connecting funnel
- 1 cable per clamp
- Actuation cover-side
- Thermoplastic enclosure
- Contact pin in actuator bridge
- 2 actuating planes
- Protection class IP20
- Inseparable cover and enclosure
- Enclosure with mounting slots
- Self-cleaning through the frictional mouvement of the contact bridges
- Lateral and bottom-side cable entry
Ordering data
Product type description | AZ 13 KD |
Article number (order number) | 101060277 |
EAN (European Article Number) | 4030661040295 |
eCl@ss number, Version 9.0 | 27-27-06-10 |
eCl@ss number, Version 11.0 | 27-27-06-10 |
ETIM number, version 6.0 | EC002592 |
ETIM number, version 7.0 | EC002592 |
General data
Standards | EN 81-20 EN 81-50 |
Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Material of the contacts, electrical | Silver-plated Cu rivets |
Material of the cover | thermoplastic, self-extinguishing |
Gross weight | 36 g |
General data - Features
Suitable for elevators | Yes |
Number of safety contacts | 1 |
Mechanical data
Actuating panels | cover-side |
Mechanical life, minimum | 1,000,000 Operations |
Actuating stroke | 7 mm |
Actuating force, approx. | 1.6 N |
Positive break force, minimum | 10 N |
Note (Positive break force) | per NC |
Mounting | Enclosure with mounting slots |
Mechanical data - Connection technique
Terminal Connector | Screw connection |
Cable entry | Single conductor version with connecting funnel |
Notes | M4, with self-opening clamping plates |
Mechanical data - Dimensions
Width | 44 mm |
Height | 55 mm |
Depth | 19 mm |
Ambient conditions
Degree of protection | IP20 |
Ambient temperature, minimum | -30 °C |
Ambient temperature, maximum | +70 °C |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 500 V |
Electrical data
Thermal test current | 4 A |
Utilisation category AC-15 | 230 VAC |
Utilisation category AC-15 | 2 A |
Utilisation category DC-13 | 200 VDC |
Utilisation category DC-13 | 2 A |
Switching element | Opener (NC) |
Switching principle | Self-cleaning pressure contact |
Scope of delivery