  • Single wire entry with Connecting funnel
  • 1 cable per clamp
  • Actuation cover-side
  • Thermoplastic enclosure
  • Contact pin in actuator bridge
  • 2 actuating planes
  • Protection class IP20
  • Inseparable cover and enclosure
  • Enclosure with mounting slots
  • Self-cleaning through the frictional mouvement of the contact bridges
  • Lateral and bottom-side cable entry

Ordering data

Product type description

AZ 13 KD

Article number (order number)

101060277

EAN (European Article Number)

4030661040295

eCl@ss number, Version 9.0

27-27-06-10

eCl@ss number, Version 11.0

27-27-06-10

ETIM number, version 6.0

EC002592

ETIM number, version 7.0

EC002592

General data

Standards

EN 81-20

EN 81-50

Enclosure material

Plastic, glass-fibre reinforced thermoplastic, self-extinguishing

Material of the contacts, electrical

Silver-plated Cu rivets

Material of the cover

thermoplastic, self-extinguishing

Gross weight

36 g

General data - Features

Suitable for elevators

Yes

Number of safety contacts

1

Mechanical data

Actuating panels

cover-side

Mechanical life, minimum

1,000,000 Operations

Actuating stroke

7 mm

Actuating force, approx.

1.6 N

Positive break force, minimum

10 N

Note (Positive break force)

per NC

Mounting

Enclosure with mounting slots

Mechanical data - Connection technique

Terminal Connector

Screw connection

Cable entry

Single conductor version with connecting funnel

Notes

M4, with self-opening clamping plates

Mechanical data - Dimensions

Width

44 mm

Height

55 mm

Depth

19 mm

Ambient conditions

Degree of protection

IP20

Ambient temperature, minimum

-30 °C

Ambient temperature, maximum

+70 °C

Ambient conditions - Insulation value

Rated insulation voltage Ui

500 V

Electrical data

Thermal test current

4 A

Utilisation category AC-15

230 VAC

Utilisation category AC-15

2 A

Utilisation category DC-13

200 VDC

Utilisation category DC-13

2 A

Switching element

Opener (NC)

Switching principle

Self-cleaning pressure contact

Scope of delivery

Included in delivery

Actuators must be ordered separately.