- Metal enclosure
- 4 or 6 Contacts
- 194 mm x 123 mm x 130 mm (basic component)
- 3 cable entries M 25 x 1.5
- Continuous adjustment of lever position 360°
Ordering data
Note (Delivery capacity) | Not available! |
Product type description | TL 471-03/03Y |
Article number (order number) | 101061151 |
EAN (European Article Number) | 4030661058375 |
Approval - Standards
Certificates | cULus CCC EAC |
General data
Standards | EN 60947-5-1 |
Active principle | mechanical |
Slide form | Castor |
Enclosure material | Grey cast iron, galvanised |
Enclosure coating material | painted |
Material of the contacts, electrical | Silver |
Roller material | Plastic |
Gross weight | 4,760 g |
General data - Features
Number of NC, left | 3 |
Number of NC, right | 3 |
Safety appraisal - Safety outputs
B10d Normally-closed contact (NC) | 2,000,000 Operations |
Mechanical data
Actuating element | Roller lever |
Mechanical life, minimum | 1,000,000 Operations |
Actuating angle, from left of switch axis | 30 ° |
Actuating angle, from right of switch axis | 30 ° |
Contact opening | 2 x 4 mm |
Actuation direction | Each time 75° right-hand side and left-hand side rotation |
Actuating speed, minimum | 0.1 mm/min |
Actuating speed, maximum | 3 m/s |
Note (Actuating speed) | Actuating speed with vertical actuating angle to switch axis |
Mechanical data - Connection technique
Terminal Connector | Screw connection |
Cable section, minimum | 1.5 mm² |
Cable section, maximum | 4 mm² |
Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Wire cross-section | 11 AWG |
Mechanical data - Dimensions
Length of sensor | 184 mm |
Width of sensor | 194 mm |
Height of sensor | 98 mm |
Width of Castor | 9 mm |
Diameter of Castor | 36 mm |
Ambient conditions
Degree of protection | IP65 to EN 60529 |
Ambient temperature, minimum | -30 °C |
Ambient temperature, maximum | +90 °C |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 500 V |
Rated impulse withstand voltage Uimp | 6 kV |
Electrical data
Thermal test current | 25 A |
Utilisation category AC-15 | 230 VAC |
Utilisation category AC-15 | 10 A |
Switching element | Opener (NC) |
Note (Switching element) | with double break |
Switching principle | Creep circuit element |
Switching frequency | 1,000 /h |