  • 1 Cable entry PG9 x 1.5
  • Thermoplastic enclosure
  • AC 2-wire
  • Double-insulated
  • Wiring compartment
  • Design M 18 x 1

Ordering data

Product type description

IFL 10-180-10/01YG

Article number (order number)

101091876

EAN (European Article Number)

4030661018317

eCl@ss number, Version 9.0

27-27-01-01

eCl@ss number, Version 11.0

27-27-01-01

ETIM number, version 6.0

EC002714

ETIM number, version 7.0

EC002714

Approval - Standards

Certificates

CCC

General data

Standards

DIN VDE 0660-208

IEC/EN 60947-5-2

Housing construction form

Cylinder, thread

Installation conditions (mechanical)

not flush

Enclosure material

Plastic

Active area

Plastic

Material of the nuts

Plastic

Material of the washer

Perbunan®

Gross weight

50 g

General data - Features

Integral System Diagnostics, status

Yes

Number of cable wires

2

Mechanical data

Tightening torque of nuts, maximum

3 Nm

Mechanical data - Switching distances according IEC 60947-5-3

Switch distance

10 mm

Mechanical data - Connection technique

Terminal Connector

Screw connection

Cable section, maximum

1 x 1.5 mm²

Mechanical data - Dimensions

ISO thread of the sensor

M18

width across flats

24 BK

Length of sensor

126 mm

Ambient conditions

Degree of protection

IP65 to EN 60529

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+70 °C

Protection rating

II

Ambient conditions - Insulation value

Rated impulse withstand voltage Uimp

4 kV

Electrical data

Voltage type

AC (alternating current)

Rated supply frequency, minimum

45 Hz

Rated supply frequency, maximum

65 Hz

Operating voltage, minimum

15 V

Operating voltage, maximum

250 V

Operating current, minimum

10 mA

Operating current

500 mA

Switching element

NO contact or NC contact

Protection circuit integrated

inductive interference protection

Switching frequency, approx.

10 Hz

Electrical data - Digital Output

Voltage drop Ud, maximum

4.5 V

Current at Voltage drop Ud

0.2 A

Versions

Two-wire

Current leakage Ir

1 mA

Status indication

Note (Integral System Diagnostics, status )

yellow LED

Notes

Note (General)

Instead of nuts, a mounting clamp can be provided.

Programmable by repositioning the plug-in jumper at the terminal screws