Бренды по алфавиту:
А Б В Г Д Е Ё Ж З И Й К Л М Н О П Р С Т У Ф Х Ц Ч Ш Щ Ъ Ы Ь Э Ю Я
Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Оплата по безналичному расчету согласно выставленному счету
Самовывоз - бесплатно, от 300руб. до пункта выдачи в Вашем городе, доставка от 500руб. "до двери"
  • Metal enclosure
  • DC 3-wire
  • Design M 18 x 1

Ordering data

Product type description

IFL 5-18-10N

Article number (order number)

101105033

EAN (European Article Number)

4030661016832

eCl@ss number, Version 9.0

27-27-01-01

eCl@ss number, Version 11.0

27-27-01-01

ETIM number, version 6.0

EC002714

ETIM number, version 7.0

EC002714

Approval - Standards

Certificates

CCC

General data

Standards

DIN VDE 0660-208

IEC/EN 60947-5-2

Housing construction form

Cylinder, thread

Installation conditions (mechanical)

flush

Enclosure material

Brass

Enclosure coating material

nickel-plated

Active area

Plastic

Material of the nuts

Brass

Gross weight

85 g

General data - Features

Integral System Diagnostics, status

Yes

Number of cable wires

3

Mechanical data

Tightening torque of nuts, maximum

18 Nm

Mechanical data - Switching distances according IEC 60947-5-3

Switch distance

5 mm

Mechanical data - Connection technique

Terminal Connector

Cable

Length of cable

2 m

Wire cross-section

0.14 mm2

Material of the Cable mantle

PVC

Mechanical data - Dimensions

ISO thread of the sensor

M18

width across flats

24 BK

Length of sensor

53 mm

Ambient conditions

Degree of protection

IP67 to EN 60529

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+70 °C

Protection rating

0

Electrical data

Voltage type

DC (direct current)

Operating voltage, minimum

10 V

Operating voltage, maximum

30 V

No-load supply current I0

3.4 mA

Operating current

200 mA

Switching element

Normally open contact (NO)

Protection circuit integrated

inductive interference protection

Protection against polarity reversal

Surge protection

Max. fuse rating

Switching frequency, approx.

400 Hz

Electrical data - Digital Output

Voltage drop Ud, maximum

1.2 V

Current at Voltage drop Ud

0.2 A

Versions

n-type

Status indication

Note (Integral System Diagnostics, status )

yellow LED

Notes

Note (General)

Instead of nuts, a mounting clamp can be provided.