Бренды по алфавиту:
А Б В Г Д Е Ё Ж З И Й К Л М Н О П Р С Т У Ф Х Ц Ч Ш Щ Ъ Ы Ь Э Ю Я
Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Оплата по безналичному расчету согласно выставленному счету
Самовывоз - бесплатно, от 300руб. до пункта выдачи в Вашем городе, доставка от 500руб. "до двери"
  • Fail-safe delay timer
  • Time adjustable from 0,1 s to 99 min
  • 3 safety contacts
  • 2 Signalling outputs

Ordering data

Note (Delivery capacity)

Phased-out product

Product type description

AZS 2305.1 110 VAC

Article number (order number)

101126704

EAN (European Article Number)

4030661058993

eCl@ss number, Version 9.0

27-37-18-19

eCl@ss number, Version 11.0

27-37-18-19

ETIM number, version 6.0

EC001449

Available until

31.12.2021

Approval - Standards

Certificates

cULus

EAC

General data

Standards

IEC/EN 60204-1

BG-GS-ET-20

EN ISO 13849-1

Enclosure material

Glass-fibre, reinforced thermoplastic

Gross weight

445 g

General data - Features

Wire breakage detection

Yes

Short-circuit recognition

Yes

Automatic reset function

Yes

Reset after disconnection of supply voltage

Yes

Earth connection detection

Yes

Integral System Diagnostics, status

Yes

Number of LEDs

1

Number of openers

1

Number of shutters

1

Number of undelayed semi-conductor outputs with signaling function

2

Number of safety contacts

3

Number of signalling outputs

2

Safety appraisal

Standards

IEC 61508

Performance level, up to

d

Control category to EN13849

3

PFH-value

1.00 x 10⁻⁷ /h

Safety Integrity Level (SIL), suitable for applications in

2

Mission Time

20 Year(s)

Mechanical data

Mounting

Snaps onto standard DIN rail to EN 60715

Mechanical data - Connection technique

Terminal Connector

Screw connection

rigid or flexible

Cable section, maximum

4 mm²

Note (Cable section)

All indications about the cable section are including the conductor ferrules.

Tightening torque of Clips

0.4 Nm

Mechanical data - Dimensions

Width

55 mm

Height

75 mm

Depth

110 mm

Ambient conditions

Degree of protection of the enclosure

IP40

Degree of protection of the mounting space

IP54

Degree of protection of clips or terminals

IP20

Ambient temperature, minimum

+0 °C

Ambient temperature, maximum

+55 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+70 °C

Resistance to vibrations to EN 60068-2-6

10 ... 55 Hz, Amplitude 0.35 mm

Restistance to shock

30 g / 11 ms

Ambient conditions - Insulation value

Rated impulse withstand voltage Uimp

4 kV

Overvoltage category

III

Degree of pollution to VDE 0110

2

Electrical data

Frequency range

50 Hz

60 Hz

Rated operating voltage

110 VAC

Rated AC voltage for controls, 50 Hz, minimum

20.4 VAC

Rated control voltage at AC 50 Hz, maximum

26.4 VAC

Rated AC voltage for controls, 60 Hz, minimum

20.4 VAC

Rated control voltage at AC 60 Hz, maximum

26.4 VAC

Electrical power consumption

5 W

Contact resistance, maximum

0.1 Ω

Note (Contact resistance)

in new state

Drop-out delay in case of power failure, typically

80 ms

Drop-out delay in case of emergency, typically

20 ms

Pull-in delay at automatic start, maximum, typically

100 ms

Pull-in delay at RESET, typically

20 ms

Electrical data - Safe relay outputs

Voltage, Utilisation category AC15

250 VAC

Current, Utilisation category AC-15

2 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

2 A

Switching capacity, minimum

10 VDC

Switching capacity, minimum

10 mA

Switching capacity, maximum

250 VAC

Switching capacity, maximum

8 A

Electrical data - Digital inputs

Input signal, HIGH Signal 1

10 … 30 VDC

Input signal, LOW Signal 0

0 … 2 VDC

Conduction resistance, maximum

40 Ω

Electrical data - Digital Output

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

0.1 A

Electrical data - Relay outputs (auxiliary contacts)

Switching capacity, maximum

24 VDC

Switching capacity, maximum

2 A

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

EMC-Directive

Integral system diagnosis (ISD)

Note (ISD -Faults)

The following faults are registered by the safety monitoring modules and indicated by ISD.

Faults

Failure of the safety relay to pull-in or drop-out

Fault on the input circuits or the relay control circuits of the safety monitoring module

Difference in time setting between channel I and channel II

Cross conclusions to the input lines

Interruption of the input connections

Other data

Note (applications)

Fail-safe delay timer

Notes

Note (General)

Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

Circuit example

Note (Wiring diagram)

The wiring diagram is shown with guard doors closed and in de-energised condition.

The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix.

To monitor one guard door at plants with dangerous run-on movements up to PL d and Category 3

Monitoring time for unlocking of solenoid interlocks

The solenoid interlock releases the guard device only when the set time has elapsed. The time begins to run when the power contactors have dropped out.