- 1 Cable entry PG9 x 1.5
- Thermoplastic enclosure
- DC 3-wire
- Wiring compartment
- Long design
- Double-insulated
- Design M 18 x 1
Ordering data
Product type description | IFL 10-180L-10/01N |
Article number (order number) | 101126737 |
EAN (European Article Number) | 4030661117720 |
eCl@ss number, Version 9.0 | 27-27-01-01 |
eCl@ss number, Version 11.0 | 27-27-01-01 |
ETIM number, version 6.0 | EC002714 |
ETIM number, version 7.0 | EC002714 |
Approval - Standards
Certificates | CCC |
General data
Standards | DIN VDE 0660-208 IEC/EN 60947-5-2 |
Housing construction form | Cylinder, thread |
Installation conditions (mechanical) | not flush |
Enclosure material | Plastic |
Active area | Plastic |
Material of the nuts | Plastic |
Material of the washer | Perbunan® |
Gross weight | 59.5 g |
General data - Features
Integral System Diagnostics, status | Yes |
Number of cable wires | 3 |
Mechanical data
Tightening torque of nuts, maximum | 3 Nm |
Mechanical data - Switching distances according IEC 60947-5-3
Switch distance | 10 mm |
Mechanical data - Connection technique
Terminal Connector | Screw connection |
Cable section, maximum | 1 x 1.5 mm² |
Mechanical data - Dimensions
ISO thread of the sensor | M18 |
width across flats | 24 BK |
Length of sensor | 125.6 mm |
Ambient conditions
Degree of protection | IP65 to EN 60529 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +70 °C |
Protection rating | II |
Electrical data
Voltage type | DC (direct current) |
Operating voltage, minimum | 10 V |
Operating voltage, maximum | 60 V |
No-load supply current I0 | 5.5 mA |
Operating current | 400 mA |
Switching element | NO contact or NC contact |
Protection circuit integrated | inductive interference protection Protection against polarity reversal |
Switching frequency, approx. | 3,500 Hz |
Electrical data - Digital Output
Voltage drop Ud, maximum | 1.5 V |
Current at Voltage drop Ud | 0.4 A |
Versions | n-type |
Status indication
Note (Integral System Diagnostics, status ) | yellow LED |
Notes
Note (General) | Instead of nuts, a mounting clamp can be provided. Programmable by repositioning the plug-in jumper at the terminal screws |