  • Metal enclosure
  • DC 4-wire
  • Long design
  • Design M30

Ordering data

Product type description

IFL 10-30L-11TP-1766

Article number (order number)

101127008

EAN (European Article Number)

4030661278162

eCl@ss number, Version 9.0

27-27-01-01

eCl@ss number, Version 11.0

27-27-01-01

ETIM number, version 6.0

EC002714

ETIM number, version 7.0

EC002714

Approval - Standards

Certificates

CCC

General data

Standards

IEC/EN 60947-5-2

DIN VDE 0660-208

Housing construction form

Cylinder, thread

Installation conditions (mechanical)

flush

Enclosure material

Brass

Enclosure coating material

nickel-plated

Active area

Plastic

Material of the nuts

Brass

Gross weight

180 g

General data - Features

Integral System Diagnostics, status

Yes

Cable sleeve

Yes

Number of cable wires

4

Mechanical data

Tightening torque of nuts, maximum

30 Nm

Mechanical data - Switching distances according IEC 60947-5-3

Switch distance

10 mm

Mechanical data - Connection technique

Terminal Connector

Cable

Length of cable

2 m

Wire cross-section

0.25 mm2

Material of the Cable mantle

Thermoflex

Mechanical data - Dimensions

ISO thread of the sensor

M30

width across flats

36 BK

Length of sensor

100 mm

Ambient conditions

Degree of protection

IP67 to EN 60529

Ambient temperature, minimum

+0 °C

Ambient temperature, maximum

+110 °C

Protection rating

0

Electrical data

Voltage type

DC (direct current)

Operating voltage, minimum

10 V

Operating voltage, maximum

60 V

No-load supply current I0

5.5 mA

Operating current

200 mA

Switching element

NO contact and NC contact (antivalent)

Protection circuit integrated

inductive interference protection

Protection against polarity reversal

Switching frequency, approx.

150 Hz

Electrical data - Digital Output

Voltage drop Ud, maximum

1 V

Current at Voltage drop Ud

0.2 A

Versions

p-type

Status indication

Note (Integral System Diagnostics, status )

yellow LED

Notes

Note (General)

Instead of nuts, a mounting clamp can be provided.