Бренды по алфавиту:
А Б В Г Д Е Ё Ж З И Й К Л М Н О П Р С Т У Ф Х Ц Ч Ш Щ Ъ Ы Ь Э Ю Я
Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Оплата по безналичному расчету согласно выставленному счету
Самовывоз - бесплатно, от 300руб. до пункта выдачи в Вашем городе, доставка от 500руб. "до двери"
  • Monitoring of BNS range magnetic safety sensors
  • 1 safety contact, STOP 0

Ordering data

Product type description

AES 1112.1 110 VAC

Article number (order number)

101128798

EAN (European Article Number)

4030661059174

eCl@ss number, Version 9.0

27-37-18-19

eCl@ss number, Version 11.0

27-37-18-19

ETIM number, version 6.0

EC001449

Approval - Standards

Certificates

BG

cULus

EAC

General data

Standards

IEC/EN 60204-1

IEC 60947-5-3

BG-GS-ET-14

BG-GS-ET-20

EN ISO 13849-1

Climatic stress

EN 60068-2-3

BG-GS-ET-14

Enclosure material

Glass-fibre reinforced thermoplastic, ventilated

Material of the contacts, electrical

AgCdO

Gross weight

160 g

General data - Features

Stop-Category

0

Wire breakage detection

Yes

Automatic reset function

Yes

Reset after disconnection of supply voltage

Yes

Integral System Diagnostics, status

Yes

Number of LEDs

1

Number of openers

2

Number of shutters

1

Number of safety contacts

1

Safety appraisal

Standards

EN ISO 13849-1

IEC 61508

Safety appraisal - Relay outputs

Performance Level, up to

c

Control category to EN13849

1

PFH-value

1.14 x 10⁻⁶ /h

Notice

for max. 50,000 switching cycles/year and max. 80% contact load

Safety Integrity Level (SIL), suitable for applications in

1

Mission time

20 Year(s)

Mechanical data

Mechanical life, minimum

10,000,000 Operations

Mounting

Snaps onto standard DIN rail to EN 60715

Mechanical data - Connection technique

Terminal Connector

Screw connection

rigid or flexible

Terminal designations

IEC/EN 60947-1

Cable section, maximum

2.5 mm²

Tightening torque of Clips

0.6 Nm

Mechanical data - Dimensions

Width

22.5 mm

Height

75 mm

Depth

110 mm

Ambient conditions

Degree of protection of the enclosure

IP40

Degree of protection of the mounting space

IP54

Degree of protection of clips or terminals

IP20

Ambient temperature, minimum

+0 °C

Ambient temperature, maximum

+55 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+70 °C

Resistance to vibrations to EN 60068-2-6

10...55 Hz, Amplitude 0.35 mm, ± 15 %

Restistance to shock

30 g / 11 ms

Ambient conditions - Insulation value

Rated impulse withstand voltage Uimp

4 kV

Overvoltage category

III

Degree of pollution to IEC/EN 60664-1

2

Electrical data

Frequency range

50 Hz

60 Hz

Thermal test current

4 A

Rated operating voltage

110 VAC

Rated AC voltage for controls, 50 Hz, minimum

93.5 VAC

Rated control voltage at AC 50 Hz, maximum

121 VAC

Rated AC voltage for controls, 60 Hz, minimum

93.5 VAC

Rated control voltage at AC 60 Hz, maximum

121 VAC

Electrical power consumption

2.4 W

Contact resistance, maximum

0.1 Ω

Note (Contact resistance)

in new state

Drop-out delay in case of power failure, typically

80 ms

Drop-out delay in case of emergency, typically

20 ms

Pull-in delay at automatic start, maximum, typically

100 ms

Pull-in delay at RESET, typically

20 ms

Electrical data - Safe relay outputs

Voltage, Utilisation category AC15

230 VAC

Current, Utilisation category AC-15

3 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

2 A

Switching capacity, minimum

10 VDC

Switching capacity, minimum

10 mA

Switching capacity, maximum

250 VAC

Switching capacity, maximum

8 A

Electrical data - Digital inputs

Conduction resistance, maximum

40 Ω

Electrical data - Digital Output

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

0.1 A

Electrical data - Relay outputs (auxiliary contacts)

Switching capacity, maximum

24 VDC

Switching capacity, maximum

2 A

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

EMC-Directive

Status indication

Indicated operating states

Authorised operation

Other data

Note (applications)

Safety sensor

Guard system

Notes

Note (General)

Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

Circuit example

Note (Wiring diagram)

The wiring diagram is shown with guard doors closed and in de-energised condition.

To secure 2 guard doors up to PL c and Category 1

Monitoring 2 guard door(s), each with a magnetic safety sensor of the BNS range

Monitoring one guard door: If only one magnetic safety sensor is connected to S1, the terminals S22, S32 and C of S2 must be bridged.

Наш менеджер свяжется с вами в ближайшее время