  • Monitoring of BNS range magnetic safety sensors
  • 2 safety contacts, STOP 0
  • 4 Signalling outputs

Ordering data

Note (Delivery capacity)

Phased-out product

Product type description

AES 3075 24 VDC

Article number (order number)

101138576

EAN (European Article Number)

4030661281360

eCl@ss number, Version 9.0

27-37-18-19

eCl@ss number, Version 11.0

27-37-18-19

ETIM number, version 6.0

EC001449

Approval - Standards

Certificates

BG

cULus

EAC

General data

Standards

IEC/EN 60204-1

IEC 60947-5-3

BG-GS-ET-14

BG-GS-ET-20

EN ISO 13849-1

Enclosure material

Glass-fibre, reinforced thermoplastic

Gross weight

379 g

General data - Features

Stop-Category

0

Wire breakage detection

Yes

Short-circuit recognition

Yes

Start input

Yes

Feedback circuit

Yes

Automatic reset function

Yes

Integral System Diagnostics, status

Yes

Number of LEDs

1

Number of openers

4

Number of shutters

4

Number of undelayed semi-conductor outputs with signaling function

4

Number of safety contacts

2

Number of signalling outputs

4

Safety appraisal

Standards

EN ISO 13849-1

IEC 61508

Safety appraisal - Relay outputs

Performance Level, up to

d

Control category to EN13849

3

PFH-value

1.00 x 10⁻⁷ /h

Notice

for max. 50,000 switching cycles/year and max. 80% contact load

Safety Integrity Level (SIL), suitable for applications in

2

Mission time

20 Year(s)

Mechanical data

Mounting

Snaps onto standard DIN rail to EN 60715

Mechanical data - Connection technique

Terminal Connector

Screw connection

Cable section, maximum

4 mm²

Note (Cable section)

All indications about the cable section are including the conductor ferrules.

Tightening torque of Clips

0.4 Nm

Mechanical data - Dimensions

Width

75 mm

Height

100 mm

Depth

110 mm

Ambient conditions

Degree of protection of the enclosure

IP40

Degree of protection of the mounting space

IP54

Degree of protection of clips or terminals

IP20

Ambient temperature, minimum

+0 °C

Ambient temperature, maximum

+55 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+70 °C

Resistance to vibrations to EN 60068-2-6

10...55 Hz, Amplitude 0.35 mm, ± 15 %

Restistance to shock

30 g / 11 ms

Ambient conditions - Insulation value

Rated impulse withstand voltage Uimp

0.5 kV

Overvoltage category

III

Degree of pollution to IEC/EN 60664-1

2

Electrical data

Frequency range

50 Hz

60 Hz

Thermal test current

4 A

Rated operating voltage

24 VAC -15% / +10%

24 VDC -10%/+20%, residual ripple max. 10%

Rated AC voltage for controls, 50 Hz, minimum

20.4 VAC

Rated control voltage at AC 50 Hz, maximum

26.4 VAC

Rated AC voltage for controls, 60 Hz, minimum

20.4 VAC

Rated control voltage at AC 60 Hz, maximum

26.4 VAC

Rated AC voltage for controls at DC minimum

20.4 VDC

Rated control voltage at DC, maximum

28.8 VDC

Electrical power consumption

8 W

Contact resistance, maximum

0.1 Ω

Note (Contact resistance)

in new state

Drop-out delay in case of power failure, typically

80 ms

Drop-out delay in case of emergency, typically

20 ms

Pull-in delay at automatic start, maximum, typically

100 ms

Pull-in delay at RESET, typically

20 ms

Electrical data - Safe relay outputs

Voltage, Utilisation category AC15

230 VAC

Current, Utilisation category AC-15

6 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

6 A

Switching capacity, minimum

10 VDC

Switching capacity, minimum

10 mA

Switching capacity, maximum

250 VAC

Switching capacity, maximum

8 A

Electrical data - Digital inputs

Input signal, HIGH Signal 1

10 … 30 VDC

Input signal, LOW Signal 0

0 … 2 VDC

Conduction resistance, maximum

40 Ω

Electrical data - Digital Output

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

0.1 A

Electrical data - Relay outputs (auxiliary contacts)

Switching capacity, maximum

24 VDC

Switching capacity, maximum

2 A

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

EMC-Directive

Integral system diagnosis (ISD)

Note (ISD -Faults)

The following faults are registered by the safety monitoring modules and indicated by ISD.

Faults

Failure of door contacts to open or close

Cross-wire or short-circuit monitoring of the switch connections

Interruption of the switch connections

Fault on the input circuits or the relay control circuits of the safety monitoring module

Other data

Note (applications)

Safety sensor

Guard system

Notes

Note (General)

Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

Circuit example

Note (Wiring diagram)

The wiring diagram is shown with guard doors closed and in de-energised condition.

The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix.

Start push button: A start push button (NO) can optionally be connected into the feedback circuit. With the guard door closed, the enabling paths are then not closed until the start push button has been operated.

The feedback circuit monitors the position of the positive-guided NC contacts of the contactors K3 and K4.

To secure 4 guard doors up to PL d and Category 3

Monitoring 4 guard door(s), each with a magnetic safety sensor of the BNS range

The NC contacts of the external contactors must be wired in series to X1 (+) and X2.

If less than 4 switches are connected, the unused terminals S21/S22 must be bridged before a NC contact is connected. This applies to the position of the jumpers in the safety-monitoring module with NC/NO configuration.

The switch (H6) connected to terminals X3 and X4 switches the enabling outputs Y14 and Y24 on and off with the guard door closed. If no switch is connected, a jumper connection must be mounted between the terminals X3 and X4.

Наш менеджер свяжется с вами в ближайшее время