Бренды по алфавиту:
А Б В Г Д Е Ё Ж З И Й К Л М Н О П Р С Т У Ф Х Ц Ч Ш Щ Ъ Ы Ь Э Ю Я
Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Оплата по безналичному расчету согласно выставленному счету
Самовывоз - бесплатно, от 300руб. до пункта выдачи в Вашем городе, доставка от 500руб. "до двери"
  • Metal enclosure
  • AC 2-wire
  • Double-insulated
  • Connector M18
  • Design M 18 x 1

Ordering data

Product type description

IFL 5-18-10ST

Article number (order number)

101141537

EAN (European Article Number)

4030661122373

eCl@ss number, Version 9.0

27-27-01-01

eCl@ss number, Version 11.0

27-27-01-01

ETIM number, version 6.0

EC002714

ETIM number, version 7.0

EC002714

Approval - Standards

Certificates

CCC

General data

Standards

DIN VDE 0660-208

IEC/EN 60947-5-2

Housing construction form

Cylinder, thread

Installation conditions (mechanical)

flush

Enclosure material

Brass

Enclosure coating material

nickel-plated

Active area

Plastic

Material of the nuts

Brass

Gross weight

55 g

General data - Features

Integral System Diagnostics, status

Yes

Number of cable wires

2

Mechanical data

Tightening torque of nuts, maximum

18 Nm

Mechanical data - Switching distances according IEC 60947-5-3

Switch distance

5 mm

Mechanical data - Connection technique

Terminal Connector

Connector M18

Mechanical data - Dimensions

ISO thread of the sensor

M18

width across flats

24 BK

Length of sensor

91 mm

Ambient conditions

Degree of protection

IP67 to EN 60529

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+70 °C

Protection rating

II

Ambient conditions - Insulation value

Rated impulse withstand voltage Uimp

4 kV

Electrical data

Voltage type

AC (alternating current)

Rated supply frequency, minimum

45 Hz

Rated supply frequency, maximum

65 Hz

Operating voltage, minimum

15 V

Operating voltage, maximum

250 V

Operating current, minimum

10 mA

Operating current

500 mA

Switching element

Normally open contact (NO)

Protection circuit integrated

inductive interference protection

Switching frequency, approx.

10 Hz

Electrical data - Digital Output

Voltage drop Ud, maximum

4.5 V

Current at Voltage drop Ud

0.2 A

Versions

Two-wire

Status indication

Note (Integral System Diagnostics, status )

yellow LED

Notes

Note (General)

Instead of nuts, a mounting clamp can be provided.

Наш менеджер свяжется с вами в ближайшее время