- Actuator head can be repositioned in steps 4 x 90°
- Metal enclosure
- Continuous adjustment of lever position 360°
- 2 Contacts
- Lever can be transposed by 180°
- In temperature-resistant version, the roller can be mounted in two different positions on the shaft
- 106 mm x 99 mm x 63 mm (basic component)
- Protection class IP65
Ordering data
Product type description | TL 441-11Y-T-1276-2/ -1801 |
Article number (order number) | 101150792 |
EAN (European Article Number) | 4030661159089 |
Approval - Standards
Certificates | CCC EAC |
General data
Standards | EN 60947-5-1 |
Active principle | mechanical |
Slide form | Castor |
Enclosure material | Grey cast iron, galvanised |
Enclosure coating material | painted |
Material of the contacts, electrical | Gold-plated silver |
Roller material | Plastic |
Gross weight | 1,760 g |
General data - Features
Number of openers | 1 |
Number of shutters | 1 |
Safety appraisal - Safety outputs
B10d Normally-closed contact (NC) | 2,000,000 Operations |
Mechanical data
Actuating element | Roller lever |
Mechanical life, minimum | 10,000,000 Operations |
Actuating angle, from left of switch axis | 30 ° |
Actuating angle, from right of switch axis | 30 ° |
Contact opening | 2 x 6 mm |
Actuating speed, minimum | 1 mm/min |
Actuating speed, maximum | 3 m/s |
Note (Actuating speed) | Actuating speed with vertical actuating angle to switch axis |
Mechanical data - Connection technique
Terminal Connector | Screw connection |
Cable section, minimum | 1.5 mm² |
Cable section, maximum | 2.5 mm² |
Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Wire cross-section | 13 AWG |
Mechanical data - Dimensions
Length of sensor | 63 mm |
Width of sensor | 106 mm |
Height of sensor | 192 mm |
Width of Castor | 9 mm |
Diameter of Castor | 36 mm |
Ambient conditions
Degree of protection | IP65 to EN 60529 |
Ambient temperature, minimum | -40 °C |
Ambient temperature, maximum | +200 °C |
Ambient conditions - Insulation value
Rated impulse withstand voltage Uimp | 6 kV |
Electrical data
Thermal test current | 16 A |
Utilisation category AC-15 | 4 A |
Switching element | NO contact, NC contact |
Note (Switching element) | with double break |
Switching principle | Creep circuit element |