- 3 Cable entry M 20 x 1.5
- Metal enclosure
- 2 Contacts
- 67 mm x 75 mm x 43 mm ( basic component)
- With large after-travel
- Actuator head with captive stainless steel ball actuator
Ordering data
Product type description | M2S 015-11Y-M20 |
Article number (order number) | 101160497 |
EAN (European Article Number) | 4030661190167 |
eCl@ss number, Version 9.0 | 27-27-06-01 |
eCl@ss number, Version 11.0 | 27-27-06-01 |
ETIM number, version 6.0 | EC000030 |
ETIM number, version 7.0 | EC000030 |
Approval - Standards
Certificates | CCC EAC |
General data
Standards | EN 60947-5-1 |
Active principle | mechanical |
Slide form | Sphere |
Enclosure material | Light-alloy diecast, paint finish |
Enclosure coating material | painted |
Material of the contacts, electrical | Silver |
Gross weight | 310 g |
General data - Features
Number of openers | 1 |
Number of shutters | 1 |
Mechanical data
Actuating element | Plunger |
Mechanical life, minimum | 10,000,000 Operations |
Actuating angle | 20 ° |
Actuating force | 15 N |
Contact opening | 2 x 1.2 mm |
Actuating speed, minimum | 1 mm/min |
Actuating speed, maximum | 1 m/s |
Note (Actuating speed) | Actuating speed with vertical actuating angle to switch axis |
Mechanical data - Connection technique
Terminal Connector | Screw connection |
Cable section, maximum | 2.5 mm² |
Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Wire cross-section | 13 AWG |
Mechanical data - Dimensions
Length of sensor | 43 mm |
Width of sensor | 67 mm |
Height of sensor | 130 mm |
Diameter of the Plunger | 10 mm |
Ambient conditions
Degree of protection | IP65 to EN 60529 |
Ambient temperature, minimum | -30 °C |
Ambient temperature, maximum | +90 °C |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 500 V |
Electrical data
Thermal test current | 10 A |
Utilisation category AC-15 | 400 VAC |
Utilisation category AC-15 | 2.5 A |
Switching element | NO contact, NC contact |
Note (Switching element) | galvanically separated contact bridges |
Switching principle | Snap switch element |
Bounce duration, maximum | 2.5 ms |
Switchover time, maximum | 40 ms |
Notes
Note (General) | Actuation from the side of the plunger should be avoided, since this reduces the mechanical life of the position switch. |