- To monitor 1 ... 4 safety edge(s)
- 1 safety contact, STOP 0
- 1 Signalling output
Ordering data
Product type description | SE-304 C AUSWERTEGERAET |
Article number (order number) | 101165883 |
EAN (European Article Number) | 4030661293622 |
eCl@ss number, Version 9.0 | 27-37-18-19 |
eCl@ss number, Version 11.0 | 27-37-18-19 |
ETIM number, version 6.0 | EC001449 |
Approval - Standards
Certificates | TÜV EAC |
General data
Standards | EN ISO 13850 EN ISO 13849-1 |
Climatic stress | EN ISO 13856-2 |
Enclosure material | Glass-fibre, thermoplastic |
Gross weight | 175 g |
Reaction time, maximum | 17 ms |
General data - Features
Stop-Category | 0 |
Electronic Fuse | Yes |
Wire breakage detection | Yes |
Short-circuit recognition | Yes |
Start input | Yes |
Feedback circuit | Yes |
Automatic reset function | Yes |
Reset edge detection | Yes |
Reset after disconnection of supply voltage | Yes |
Earth connection detection | Yes |
Integral System Diagnostics, status | Yes |
Number of LEDs | 5 |
Number of undelayed semi-conductor outputs with signaling function | 1 |
Number of safety contacts | 1 |
Number of signalling outputs | 1 |
Safety appraisal
Performance level, up to | d |
Control category to EN13849 | 3 |
Control category to EN954 | 3 |
PFH-value | 1.01 x 10⁻⁷ /h |
Note (PFH-value) | up to max. 5,000 switching cycles/year |
Mission Time | 20 Year(s) |
Mechanical data
Mechanical life, minimum | 10,000,000 Operations |
Mounting | Snaps onto standard DIN rail to EN 60715 |
Mechanical data - Connection technique
Terminal Connector | Screw connection |
Length of cable | 200 m |
Cable section, maximum | 2 x 1.5 mm² |
Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Mechanical data - Dimensions
Width | 22.5 mm |
Height | 100 mm |
Depth | 121 mm |
Ambient conditions
Degree of protection of the enclosure | IP40 |
Degree of protection of the mounting space | IP54 |
Degree of protection of clips or terminals | IP20 |
Ambient temperature, minimum | +5 °C |
Ambient temperature, maximum | +55 °C |
Resistance to vibrations to EN 60068-2-6 | 10 … 55 Hz, amplitude 0.15 mm |
Ambient conditions - Insulation value
Rated impulse withstand voltage Uimp | 4 kV |
Overvoltage category | III |
Degree of pollution to VDE 0110 | 2 |
Electrical data
Frequency range | 50 Hz |
Rated operating voltage | 24 VDC +20% / -10% 24 VAC +10% / -10% |
Operating current | 500 mA |
Rated AC voltage for controls, 50 Hz, minimum | 21.6 VAC |
Rated control voltage at AC 50 Hz, maximum | 28.8 VAC |
Rated AC voltage for controls at DC minimum | 21.6 VDC |
Rated control voltage at DC, maximum | 28.8 VDC |
Utilisation category AC-15 | 230 VAC |
Utilisation category AC-15 | 2 A |
Utilisation category DC-13 | 24 VDC |
Utilisation category DC-13 | 2 A |
Electrical power consumption, maximum | 4 W |
Pull-in delay at RESET | 100 ms ... 2000 ms |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating | EMC-Directive |
Status indication
Indicated operating states | Authorised operation fault indication |
Other data
Note (applications) | Safety edges |
Notes
Note (General) | The overall machine safety depends on the professional mounting and installation of the safety monitoring module and the signal transmitter, as well as on the correct and professional electrical connection of the components. If there it any risk whatsoever, the machine may not be restarted. |
Circuit example
Note (Wiring diagram) | Both re-initialisation and auto-reset must comply with the requirements of EN 1760-2 (diagram A2, A3). The wiring diagram is shown for the de-energised condition. Monitoring the safety edges SE 40 / SE 70 with a safety monitoring unit SE-304C up to PL d and Category 3. Manual reset function or auto-reset: the manual reset function is triggered by an edge-sensitive signal (edge switching '0-1-0' within 100 ms up to 2 s) (X2/X3). Alternatively, the auto-reset function can be activated by a connection (A3/X2). If less than 4 safety edges are connected, the following diagram must be observed. |