Бренды по алфавиту:
А Б В Г Д Е Ё Ж З И Й К Л М Н О П Р С Т У Ф Х Ц Ч Ш Щ Ъ Ы Ь Э Ю Я
Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Оплата по безналичному расчету согласно выставленному счету
Самовывоз - бесплатно, от 300руб. до пункта выдачи в Вашем городе, доставка от 500руб. "до двери"
  • NOTICE: Not available! (Replacement: SLC 425I)
  • Control Category 4

Ordering data

Note (Delivery capacity)

Not available!

Product type description

SLC415I-E/R0460-40-12

Article number (order number)

101170404

eCl@ss number, Version 9.0

27-27-27-04

eCl@ss number, Version 11.0

27-27-27-04

General data

Standards

IEC/EN 61496-1/-2

Enclosure material

Aluminium

Reaction time, maximum

11 ms

General data - Features

Muting function

Yes

Override

Yes

Restart interlock (manual reset)

Yes

Beam coding available

Yes

Integral System Diagnostics, status

Yes

Integral System Diagnostics

Yes

Number of beams

15

Number of fail-safe digital outputs

2

Safety appraisal

Safety type in accordance with IEC 61496-1

4

Mechanical data

Detection ability for test bodies at v = 1.6 m/s

40 mm

Height of the protection field

460 mm

Range, protection field, minimum

0 mm

Range, protection field, maximum

16,000 mm

Wave length of the sensor

950 nm

Mechanical data - Connection technique

Terminal Connector

Connector

Terminal connector, Recipient

Connector plug M23, 19-pole

Terminal, Connector, Transmitter

Connector plug M12, 5-pole

Length of the connectable cable, maximum

100 m

Mechanical data - Dimensions

Length of sensor

50 mm

Width of sensor

60 mm

Height of sensor

586 mm

Ambient conditions

Degree of protection

IP65 to EN 60529

Ambient temperature, minimum

+0 °C

Ambient temperature, maximum

+55 °C

Storage and transport temperature, minimum

-20 °C

Storage and transport temperature, maximum

+70 °C

Protection rating

III

Electrical data

Voltage type

DC (direct current)

Switching voltage OSSD, HIGH signal

24 V

Electrical power consumption of the receiver

6 W

Electrical power consumption of the transmitter

3 W

Electrical data - Fail-safe digital outputs

Output current, (fail-safe output), maximum

0.5 A

Versions

p-type

Scope of delivery

Included in delivery

Emitter + receiver, mounting angle, T-slot nuts

Accessory

Recommended safety switchgear

SCR 402R-301

Notes

Note (General)

Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 0.3 mA.

2 or 4 muting sensors can be connected.

The muting sensors (e.g. LF 50) must be ordered separately.

Наш менеджер свяжется с вами в ближайшее время