Бренды по алфавиту:
А Б В Г Д Е Ё Ж З И Й К Л М Н О П Р С Т У Ф Х Ц Ч Ш Щ Ъ Ы Ь Э Ю Я
Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Оплата по безналичному расчету согласно выставленному счету
Самовывоз - бесплатно, от 300руб. до пункта выдачи в Вашем городе, доставка от 500руб. "до двери"
  • Metal enclosure
  • 1 Contact
  • 106 mm x 71 mm x 63 mm (basic component)
  • Protection class IP65

Ordering data

Product type description

T. 422-01Y-M20

Article number (order number)

101170462

EAN (European Article Number)

4030661297712

Approval - Standards

Certificates

CCC

EAC

General data

Standards

EN 60947-5-1

Active principle

mechanical

Slide form

Sphere

Enclosure material

Grey cast iron, galvanised

Enclosure coating material

painted

Material of the contacts, electrical

Silver

Gross weight

1,070 g

General data - Features

Number of openers

1

Safety appraisal - Safety outputs

B10d Normally-closed contact (NC)

2,000,000 Operations

Mechanical data

Actuating element

Plunger

Actuating angle

20 °

Contact opening

2 x 6 mm

Actuating speed, minimum

1 mm/min

Actuating speed, maximum

1 m/s

Note (Actuating speed)

Actuating speed with vertical actuating angle to switch axis

Mechanical data - Connection technique

Terminal Connector

Screw connection

Cable section, minimum

1.5 mm²

Cable section, maximum

2.5 mm²

Note (Cable section)

All indications about the cable section are including the conductor ferrules.

Wire cross-section

13 AWG

Mechanical data - Dimensions

Length of sensor

63 mm

Width of sensor

106 mm

Height of sensor

97 mm

Diameter of the Plunger

10 mm

Ambient conditions

Degree of protection

IP65 to EN 60529

Ambient temperature, minimum

-30 °C

Ambient temperature, maximum

+90 °C

Electrical data

Thermal test current

16 A

Utilisation category AC-15

4 A

Switching element

Opener (NC)

Note (Switching element)

with double break

Notes

Note (General)

Actuation from the side of the plunger should be avoided, since this reduces the mechanical life of the position switch.

Наш менеджер свяжется с вами в ближайшее время