- Metal enclosure
- 4 Contacts
- 62 mm x 127 mm x 50 mm ( basic component)
- Switching points and contact function adjustable
- 3 cable entries M 20 x 1.5
Ordering data
Product type description | US 434Y-M20 |
Article number (order number) | 101176035 |
EAN (European Article Number) | 4030661306339 |
eCl@ss number, Version 9.0 | 27-27-06-01 |
eCl@ss number, Version 11.0 | 27-27-06-01 |
ETIM number, version 6.0 | EC000030 |
ETIM number, version 7.0 | EC000030 |
Approval - Standards
Certificates | cULus EAC |
General data
Standards | EN 60947-5-1 |
Active principle | mechanical |
Slide form | Sphere |
Enclosure material | Light alloy die-casting |
Enclosure coating material | painted |
Material of the contacts, electrical | Silver |
Gross weight | 435 g |
General data - Features
Number of openers | 2 |
Number of shutters | 2 |
Safety appraisal - Safety outputs
B10d Normally-closed contact (NC) | 2,000,000 Operations |
Mechanical data
Actuating element | Plunger |
Mechanical life, minimum | 10,000,000 Operations |
Actuating angle | 20 ° |
Contact opening | 2 x 1.5 mm |
Actuating speed, minimum | 1 mm/min |
Actuating speed, maximum | 1 m/s |
Note (Actuating speed) | Actuating speed with vertical actuating angle to switch axis |
Mechanical data - Connection technique
Terminal Connector | Screw connection |
Cable section, minimum | 1.5 mm² |
Cable section, maximum | 2.5 mm² |
Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Wire cross-section | 13 AWG |
Mechanical data - Dimensions
Length of sensor | 50 mm |
Width of sensor | 62 mm |
Height of sensor | 138 mm |
Diameter of the Plunger | 6 mm |
Ambient conditions
Degree of protection | IP65 to EN 60529 |
Ambient temperature, minimum | -20 °C |
Ambient temperature, maximum | +60 °C |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 500 V |
Electrical data
Thermal test current | 16 A |
Switching element | NC contact NO contact |
Switching principle | Creep circuit element |
Notes
Note (General) | Type of contact and switching points can be factory set to order. Actuation from the side of the plunger should be avoided, since this reduces the mechanical life of the position switch. |