- Suitable for the signal processing of outputs with contact sensors
- 2 safety contacts, STOP 0
- 6 Signalling outputs
- Multi-evaluation of up to 6 safety guards
- Suitable for the signal processing of outputs with contact sensors
Ordering data
Product type description | SRB207AN 230VAC |
Article number (order number) | 101176472 |
EAN (European Article Number) | 4250116202041 |
eCl@ss number, Version 9.0 | 27-37-18-19 |
eCl@ss number, Version 11.0 | 27-37-18-19 |
ETIM number, version 6.0 | EC001449 |
Replacement article number | 101196817 |
Available until | 31.12.2022 |
Approval - Standards
Certificates | cULus EAC |
General data
Standards | IEC 61508 IEC/EN 60204-1 EN 60947-5-1 EN ISO 13849-1 |
Climatic stress | EN 60068-2-78 |
Enclosure material | Glass-fibre reinforced thermoplastic, ventilated |
Material of the contacts, electrical | AgSn0. self-cleaning, positive drive |
Gross weight | 400 g |
General data - Features
Stop-Category | 0 |
Electronic Fuse | Yes |
Wire breakage detection | Yes |
Short-circuit recognition | Yes |
Removable Terminals | Yes |
Start input | Yes |
Feedback circuit | Yes |
Automatic reset function | Yes |
Reset edge detection | Yes |
Earth connection detection | Yes |
Integral System Diagnostics, status | Yes |
Number of auxiliary contacts | 1 7 |
Number of LEDs | 3 |
Number of safety contacts | 2 |
Number of Snap-in contacts, maximum | 6 |
Number of Snap-in contacts, minimum | 1 |
Number of signalling outputs | 6 |
Safety appraisal
Standards | EN 60947-5-1 IEC 61508 |
Safety appraisal - Relay outputs
Performance Level, up to | e |
Control category to EN13849 | 3 |
Diagnostic Coverage (DC) Level | >, 99 % |
PFH-value | 2.00 x 10⁻⁸ /h |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Common Cause Failure (CCF), minimum | 65 |
Mechanical data
Mechanical life, minimum | 10,000,000 Operations |
Mounting | Snaps onto standard DIN rail to EN 60715 |
Mechanical data - Connection technique
Terminal Connector | Screw connection rigid or flexible |
Terminal designations | IEC/EN 60947-1 |
Cable section, minimum | 0.25 mm² |
Cable section, maximum | 2.5 mm² |
Tightening torque of Clips | 0.6 Nm |
Mechanical data - Dimensions
Width | 45 mm |
Height | 100 mm |
Depth | 121 mm |
Ambient conditions
Degree of protection of the enclosure | IP40 |
Degree of protection of the mounting space | IP54 |
Degree of protection of clips or terminals | IP20 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +45 °C |
Storage and transport temperature, minimum | -40 °C |
Storage and transport temperature, maximum | +85 °C |
Resistance to vibrations to EN 60068-2-6 | 10...55 Hz, Amplitude 0.35 mm, ± 15 % |
Restistance to shock | 30 g / 11 ms |
Ambient conditions - Insulation value
Rated impulse withstand voltage Uimp | 4 kV |
Overvoltage category | III |
Degree of pollution to IEC/EN 60664-1 | 2 |
Electrical data
Frequency range | 50 Hz 60 Hz |
Rated operating voltage | 48 ... 240 VAC |
Rated AC voltage for controls, 50 Hz, minimum | 48 VAC |
Rated control voltage at AC 50 Hz, maximum | 240 VAC |
Rated AC voltage for controls, 60 Hz, minimum | 48 VAC |
Rated control voltage at AC 60 Hz, maximum | 240 VAC |
Rated AC voltage for controls at DC minimum | 20.4 VDC |
Rated control voltage at DC, maximum | 28.8 VDC |
Electrical power consumption | 6.8 W |
Contact resistance, maximum | 0.1 Ω |
Note (Contact resistance) | in new state |
Drop-out delay in case of power failure, typically | 80 ms |
Drop-out delay in case of emergency, typically | 20 ms |
Pull-in delay at automatic start, maximum, typically | 100 ms |
Pull-in delay at RESET, typically | 20 ms |
Switching frequency, maximum | 3 Hz |
Electrical data - Safe relay outputs
Voltage, Utilisation category AC15 | 230 VAC |
Current, Utilisation category AC-15 | 6 A |
Voltage, Utilisation category DC13 | 24 VDC |
Current, Utilisation category DC13 | 6 A |
Switching capacity, minimum | 10 VDC |
Switching capacity, minimum | 10 mA |
Switching capacity, maximum | 250 VAC |
Switching capacity, maximum | 8 A |
Electrical data - Digital inputs
Conduction resistance, maximum | 40 Ω |
Electrical data - Digital Output
Voltage, Utilisation category DC12 | 24 VDC |
Current, Utilisation category DC12 | 0.1 A |
Electrical data - Relay outputs (auxiliary contacts)
Switching capacity, maximum | 24 VDC |
Switching capacity, maximum | 2 A |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating | EMC-Directive |
Status indication
Indicated operating states | Position relay K2 Position relay K1 Internal operating voltage Ui |
Other data
Note (applications) | Safety sensor Guard system Emergency-Stop button Pull-wire emergency stop switches |
Notes
Note (General) | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
Circuit example
Note (Wiring diagram) | The wiring diagram is shown with guard doors closed and in de-energised condition. The feedback circuit monitors the position of the contactors K3 and K4. Automatic start: The automatic start is programmed by connecting the feedback circuit to the terminals X1/X3. If the feedback circuit is not required, establish a bridge. To secure 6 guard doors up to PL d and Category 3 Monitoring 6 guard door(s), each with a magnetic safety sensor of the BNS range Start button (S) with edge detection |