- for shaft heights up to 130
- Different interfaces for the connection to different controllers
- low installation cost / little installation effort
- Wear- and maintenance-free
- Absolute values accurate down to the last millimeter
Ordering data
Product type description | USP-100-CANOPEN |
Article number (order number) | 101178038 |
eCl@ss number, Version 9.0 | 27-20-10-01 |
eCl@ss number, Version 11.0 | 27-20-10-01 |
Approval - Standards
Certificates | cULus EAC |
General data
Enclosure material | Ultramid |
Gross weight | 1,425 g |
Mechanical data
Repeat accuracy R (under normal elevator ratios) | 1 mm |
Repeat accuracy R (at calibration temperature) | 1 mm |
Travel distance, maximum | 130 m |
Conveying speed, maximum | 6 m/s |
Ambient conditions
Degree of protection | max. IP54 depending on the USP receiver cable |
Ambient temperature, minimum | -20 °C |
Ambient temperature, maximum | +60 °C |
Electrical data
Rated operating voltage | 24 VDC +15% / -10% |
Operating current | 180 mA |
Electrical data - Electromagnetic compatibility (EMC)
Interfering radiation | EN 50081-2 EN 12015 |
EMC rating | IEC 61000-6-2 EN 12016 |
Scope of delivery
Included in delivery | The USP kit comprises: transmitter + receiver, 2 dampers, 1 vibration protection, mounting materials, documentation, signal wire, the transmitter connecting cable and the receiver cable are related to the respective application and must be ordered separately. |
Notes
Note (General) | The specifications with regard to the protection class are related to the entire USP system. Please observe the information contained in the mounting instructions To fit the USP system elements in the elevator shaft, only conventional tools are required. |
Note (Interface) | Suitable for the following controllers: Böhnke + Partner, Langer & Laumann, Weber Lifttechnik |