Бренды по алфавиту:
А Б В Г Д Е Ё Ж З И Й К Л М Н О П Р С Т У Ф Х Ц Ч Ш Щ Ъ Ы Ь Э Ю Я
Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Оплата по безналичному расчету согласно выставленному счету
Самовывоз - бесплатно, от 300руб. до пункта выдачи в Вашем городе, доставка от 500руб. "до двери"
  • Suitable for the signal processing of outputs with contact sensors
  • Possibility to connect a non-contact end switch or speed reduction switch
  • 2 safety contacts, switch-off level 1,

    2 safety contacts, switch-off level 2
  • 2 Signalling outputs

Ordering data

Product type description

SRB402NE 230V

Article number (order number)

101178397

EAN (European Article Number)

4250116202423

eCl@ss number, Version 9.0

27-37-18-19

eCl@ss number, Version 11.0

27-37-18-19

ETIM number, version 6.0

EC001449

Replacement article number

101178532

Approval - Standards

Certificates

EAC

General data

Standards

IEC 61508

EN 60947-5-1

EN 60204-1

EN ISO 13849-1

Climatic stress

EN 60068-2-78

Enclosure material

Glass-fibre reinforced thermoplastic, ventilated

Material of the contacts, electrical

Ag-Ni, self-cleaning, positive drive

Gross weight

550 g

General data - Features

Stop-Category

0

Wire breakage detection

Yes

Short-circuit recognition

Yes

Removable Terminals

Yes

Feedback circuit

Yes

Automatic reset function

Yes

Earth connection detection

Yes

Integral System Diagnostics, status

Yes

Number of auxiliary contacts

2

Number of LEDs

7

Number of openers

4

Number of safety contacts

4

Number of signalling outputs

2

Safety appraisal

Standards

IEC/EN 60947-1

IEC 61508

Safety appraisal - Relay outputs

PFH-value

2.00 x 10⁻⁸ /h

Performance level, stop 0, up to

e

Category, Stop 0

4

Diagnostic Coverage (DC) Level, Stop 0

≥ 99 %

Safety Integrity Level (SIL), Stop 0, suitable for applications in

3

Mission time

20 Year(s)

Common Cause Failure (CCF), minimum

65

Mechanical data

Mechanical life, minimum

10,000,000 Operations

Mounting

Snaps onto standard DIN rail to EN 60715

Mechanical data - Connection technique

Terminal Connector

Screw connection

rigid or flexible

Terminal designations

IEC/EN 60947-1

Cable section, minimum

0.25 mm²

Cable section, maximum

2.5 mm²

Tightening torque of Clips

0.6 Nm

Mechanical data - Dimensions

Width

45 mm

Height

100 mm

Depth

121 mm

Ambient conditions

Degree of protection of the enclosure

IP40

Degree of protection of the mounting space

IP54

Degree of protection of clips or terminals

IP20

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+45 °C

Storage and transport temperature, minimum

-40 °C

Storage and transport temperature, maximum

+85 °C

Resistance to vibrations to EN 60068-2-6

10...55 Hz, Amplitude 0.35 mm, ± 15 %

Restistance to shock

30 g / 11 ms

Ambient conditions - Insulation value

Rated impulse withstand voltage Uimp

4 kV

Overvoltage category

III

Degree of pollution to IEC/EN 60664-1

2

Electrical data

Frequency range

50 Hz

60 Hz

Rated operating voltage

230 VAC -15% / + 10%

Rated AC voltage for controls, 50 Hz, minimum

195.5 VAC

Rated control voltage at AC 50 Hz, maximum

253 VAC

Rated AC voltage for controls, 60 Hz, minimum

195.5 VAC

Rated control voltage at AC 60 Hz, maximum

253 VAC

Electrical power consumption

6 W

Electrical power consumption

7.8 VA

Contact resistance, maximum

0.1 Ω

Note (Contact resistance)

in new state

Drop-out delay in case of power failure, typically

80 ms

Drop-out delay in case of emergency, typically

20 ms

Pull-in delay at automatic start, maximum, typically

100 ms

Pull-in delay at RESET, typically

20 ms

Electrical data - Safe relay outputs

Voltage, Utilisation category AC15

230 VAC

Current, Utilisation category AC-15

4 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

4 A

Switching capacity, minimum

10 VDC

Switching capacity, minimum

10 mA

Switching capacity, maximum

250 VAC

Switching capacity, maximum

8 A

Electrical data - Digital inputs

Conduction resistance, maximum

40 Ω

Electrical data - Relay outputs (auxiliary contacts)

Switching capacity, maximum

24 VDC

Switching capacity, maximum

2 A

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

EMC-Directive

Status indication

Indicated operating states

Position relay K2

Position relay K1

Internal operating voltage Ui

Position relay K3

Position relay K5

Other data

Note (applications)

Safety sensor

Guard system

Notes

Note (General)

Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

Circuit example

Note (Wiring diagram)

The control system recognises wire-breakage and earth faults in the monitoring circuit.

The example shows a 1-channel control with contact A for a guard door monitor, of which at least one contact has positive break, with external reset button (R).

Relay outputs: Suitable for 1 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts.

The wiring diagram is shown with non-actuated limit switches and in de-energised condition.

(H2) = Feedback circuit

Наш менеджер свяжется с вами в ближайшее время