- 2 cable entries M 16 x 1.5
- with fixed switching angle
- Metal enclosure
- Good resistance to oil and petroleum spirit
- For left or right hinged doors
- 141 mm x 115 mm x 21,5 mm
- Simple mounting, suitable for all conventional profile systems (30 … 60 mm)
Ordering data
Product type description | TESF/S/CC/0 |
Article number (order number) | 101182707 |
EAN (European Article Number) | 4030661449005 |
eCl@ss number, Version 9.0 | 27-27-06-09 |
eCl@ss number, Version 11.0 | 27-27-06-09 |
ETIM number, version 6.0 | EC002591 |
ETIM number, version 7.0 | EC002591 |
Approval - Standards
Certificates | cULus CCC EAC |
General data
Standards | EN 60947-5-1 BG-GS-ET-15 |
Enclosure material | Zinc die-cast |
Material of the contacts, electrical | Silver-nickel alloy 10 |
Colour of the housing | Black |
Gross weight | 616 g |
General data - Features
Mounting outside | Yes |
Number of auxiliary contacts | 2 |
Number of safety contacts | 2 |
Safety appraisal
Standards | EN ISO 13849-1 |
Mission Time | 20 Year(s) |
Safety appraisal - Safety outputs
B10d Normally-closed contact (NC) | 2,000,000 Operations |
B10d Normally open contact (NO) | 1,000,000 Operations |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Positive break angle | 14 ° |
Opening angle | 180° |
Mechanical data - Connection technique
Terminal Connector | Spring pulley connection |
Cable section, minimum | 0.5 mm² |
Cable section, maximum | 1 mm² |
Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Mechanical data - Dimensions
Length of sensor | 21.5 mm |
Width of sensor | 141 mm |
Height of sensor | 115 mm |
Ambient conditions
Degree of protection | IP65 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +65 °C |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2.5 kV |
Electrical data
Thermal test current | 2.5 A |
Utilisation category AC-15 | 230 VAC |
Utilisation category AC-15 | 2 A |
Utilisation category DC-13 | 24 VDC |
Utilisation category DC-13 | 1 A |
Switching element | NO contact, NC contact |
Switching principle | Creep circuit element |
Switching frequency | 1,200 /h |
Notes
Note (General) | Closed guard device = 0° in contact switch travel diagrams. The factory-set switching angle is 3°. Until the limit of the mechanical life has been reached the angle can increase up to 8° under normal wear-out conditions. The positive break angle is 5°. |