- Single wire entry (1 cable per clamp)
- Thermoplastic enclosure
- Contact pin in actuator bridge
- 1 Actuating planes
- Protection class IP20
- Inseparable cover and enclosure
- Enclosure with mounting slots
- Self-cleaning through the frictional mouvement of the contact bridges
Ordering data
Product type description | AZ08K |
Article number (order number) | 101183494 |
EAN (European Article Number) | 4030661332710 |
eCl@ss number, Version 9.0 | 27-27-06-10 |
eCl@ss number, Version 11.0 | 27-27-06-10 |
ETIM number, version 6.0 | EC002592 |
ETIM number, version 7.0 | EC002592 |
Approval - Standards
Certificates | TÜV EAC |
General data
Standards | EN 81 |
Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Material of the contacts, electrical | Silver-plated Cu rivets |
Gross weight | 27 g |
General data - Features
Suitable for elevators | Yes |
Number of safety contacts | 1 |
Mechanical data
Actuating panels | 1 |
Mechanical life, minimum | 1,000,000 Operations |
Actuating stroke | 5 mm |
Actuating force, approx. | 2 N |
Mounting | Enclosure with mounting slots |
Mechanical data - Connection technique
Terminal Connector | Screw terminals M 3 |
Cable entry | Single conductor version with connecting funnel |
Cable section, minimum | 0.75 mm² |
Cable section, maximum | 2.5 mm² |
Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Mechanical data - Dimensions
Width | 73.5 mm |
Height | 27 mm |
Depth | 21.5 mm |
Ambient conditions
Degree of protection | IP20 to DIN VDE 0470-1 IP20 to EN 60529 |
Ambient temperature, minimum | -30 °C |
Ambient temperature, maximum | +80 °C |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 500 V |
Electrical data
Thermal test current | 4 A |
Utilisation category AC-15 | 230 VAC |
Utilisation category AC-15 | 2 A |
Utilisation category DC-13 | 200 VDC |
Utilisation category DC-13 | 2 A |
Switching element | Opener (NC) |
Switching principle | Self-cleaning pressure contact |
Scope of delivery
Included in delivery | Actuators must be ordered separately. |