- 3 cable entries M 20 x 1.5
- Metal enclosure
- one-side operation / wire up to 75 m long
- Release push button
- Position indicator
- Robust design
- Large wiring compartment
- Twisting of towing eye not possible
- External watertight collar
- wire pull and breakage detection
Ordering data
Product type description | ZQ 900-04N |
Article number (order number) | 101184477 |
EAN (European Article Number) | 4030661333694 |
eCl@ss number, Version 9.0 | 27-37-12-01 |
eCl@ss number, Version 11.0 | 27-37-12-01 |
ETIM number, version 6.0 | EC002026 |
Approval - Standards
Certificates | TÜV EAC |
General data
Standards | IEC/EN 60947-5-1 EN ISO 13850 IEC/EN 60947-5-5 |
Enclosure material | Zinc die-cast |
Enclosure coating material | painted |
Material of the contacts, electrical | Silver |
Material of the cover | Glass-fibre, thermoplastic |
Length of the wire, maximum | 75 m |
Gross weight | 1,275 g |
General data - Features
Emergency-Stop button | Yes |
Indicator lamp | No |
Number of safety contacts | 4 |
Safety appraisal
Standards | EN ISO 13849-1 |
Mission Time | 20 Year(s) |
Safety appraisal - Safety outputs
B10d Normally-closed contact (NC) | 100,000 Operations |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Mechanical data - Connection technique
Terminal Connector | Screw connection |
Cable section, minimum | 0.75 mm² |
Cable section, maximum | 2.5 mm² |
Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Mechanical data - Dimensions
Length of sensor | 97.2 mm |
Width of sensor | 71.5 mm |
Height of the Sensor, minimum | 220.3 mm |
Height of the Sensor, maximum | 236.3 mm |
Ambient conditions
Degree of protection | IP65 to EN 60529 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +70 °C |
Relative humidity, maximum | 95 % |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 500 V |
Rated impulse withstand voltage Uimp | 6 kV |
Electrical data
Thermal test current | 6 A |
Utilisation category AC-15 | 230 VAC |
Utilisation category AC-15 | 4 A |
Utilisation category DC-13 | 24 VDC |
Utilisation category DC-13 | 1 A |
Switching element | Opener (NC) |
Switching principle | Snap switch element |
Notes
Note (General) | For lengths of over 10 m, intermediate wire supports must be installed every 3 to 5 m. Recommended cable lengths for pull-wire Emergency-Stop switches in relation to the range of ambient temperature. As the thimbles are subject to deformation in case of wire pull, the wire should be pulled several times after fitting. After that, the wire must be re-tensioned using the eyebolt or the tensioner. The screwed G24-M20 indicator lamp must be ordered separately, see accessories. |