Бренды по алфавиту:
А Б В Г Д Е Ё Ж З И Й К Л М Н О П Р С Т У Ф Х Ц Ч Ш Щ Ъ Ы Ь Э Ю Я
Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Оплата по безналичному расчету согласно выставленному счету
Самовывоз - бесплатно, от 300руб. до пункта выдачи в Вашем городе, доставка от 500руб. "до двери"
  • NOTICE: Not available! (Replacement: SLC 420)
  • Control Category 4

Ordering data

Note (Delivery capacity)

Not available!

Product type description

FLC 410-E/R1660-14-B

Article number (order number)

101185993

eCl@ss number, Version 9.0

27-27-27-04

eCl@ss number, Version 11.0

27-27-27-04

General data

Standards

IEC/EN 61496-1/-2

Enclosure material

Aluminium

Reaction time, maximum

25 ms

General data - Features

Beam coding available

Yes

Hide function

Yes

Integral System Diagnostics, status

Yes

Integral System Diagnostics

Yes

Number of beams

165

Number of fail-safe digital outputs

2

Safety appraisal

Safety type in accordance with IEC 61496-1

4

Mechanical data

Detection ability for test bodies at v = 1.6 m/s

14 mm

Height of the protection field

1,660 mm

Range, protection field, minimum

0 mm

Range, protection field, maximum

5,000 mm

Wave length of the sensor

950 nm

Mechanical data - Connection technique

Terminal Connector

Connector

Terminal connector, Recipient

Connector plug M12, 8-pole

Terminal, Connector, Transmitter

Connector plug M12, 5-pole

Length of the connectable cable, maximum

100 m

Mechanical data - Dimensions

Length of sensor

35 mm

Width of sensor

45 mm

Height of sensor

1,761 mm

Ambient conditions

Degree of protection

IP65 to EN 60529

Ambient temperature, minimum

+0 °C

Ambient temperature, maximum

+55 °C

Storage and transport temperature, minimum

-20 °C

Storage and transport temperature, maximum

+70 °C

Protection rating

III

Electrical data

Voltage type

DC (direct current)

Switching voltage OSSD, HIGH signal

24 V

Electrical power consumption of the receiver

3 W

Electrical power consumption of the transmitter

2 W

Electrical data - Fail-safe digital outputs

Output current, (fail-safe output), maximum

0.5 A

Versions

p-type

Scope of delivery

Included in delivery

Emitter + receiver, mounting angle, T-slot nuts

Accessory

Recommended safety switchgear

SCR 402R-301

Notes

Note (General)

Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 0.3 mA.