Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
- NOTICE: Not available! (Replacement: SLG 422)
- Integrated start/restart interlock
- Integrated contactor control
- Status display
- Optical sychronisation
- Fail-safe transistor outputs
- Control Category 4
Ordering data
Note (Delivery capacity) | Not available! |
Product type description | SLG 412-E/R0800-03-12 |
Article number (order number) | 101186046 |
eCl@ss number, Version 9.0 | 27-27-27-03 |
eCl@ss number, Version 11.0 | 27-27-27-03 |
General data
Standards | IEC/EN 61496-1/-2 |
Design of multi-ray photoelectric barrier | Emitter and receiver, separated |
Enclosure material | Aluminium |
Beam distance | 400 mm |
Gross weight | 6,000 g |
Reaction time, maximum | 7 ms |
General data - Features
Preliminary failure signal | Yes |
Restart interlock (manual reset) | Yes |
Beam coding available | Yes |
Integral System Diagnostics, status | Yes |
Integral System Diagnostics | Yes |
Number of beams | 3 |
Number of semi-conductor outputs with signaling function | 1 |
Number of fail-safe digital outputs | 2 |
Safety appraisal
Safety type in accordance with IEC 61496-1 | 4 |
Mechanical data
Height of the protection field | 810 mm |
Range, protection field, minimum | 0 mm |
Range, protection field, maximum | 16,000 mm |
Wave length of the sensor | 950 nm |
Mechanical data - Connection technique
Terminal Connector | Connector |
Terminal connector, Recipient | Connector plug M23, 19-pole |
Terminal, Connector, Transmitter | Connector plug M12, 5-pole |
Mechanical data - Dimensions
Length of sensor | 50 mm |
Width of sensor | 60 mm |
Height of sensor | 1,036 mm |
Ambient conditions
Degree of protection | IP65 to EN 60529 |
Ambient temperature, minimum | +0 °C |
Ambient temperature, maximum | +55 °C |
Storage and transport temperature, minimum | -20 °C |
Storage and transport temperature, maximum | +70 °C |
Protection rating | III |
Electrical data
Voltage type | DC (direct current) |
Switching voltage OSSD, HIGH signal | 24 V |
Electrical power consumption of the receiver | 6 W |
Electrical power consumption of the transmitter | 3 W |
Length of cable, maximum | 100 m |
Electrical data - Fail-safe digital outputs
Output current, (fail-safe output), maximum | 0.5 A |
Versions | p-type |
Scope of delivery
Included in delivery | Emitter + receiver, mounting angle, T-slot nuts |
Accessory
Recommended safety switchgear | SCR 402R-301 |
Notes
Note (General) | Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 0.3 mA. |