- Large wiring compartment
- Manual release, cover-side
- cable entries 4 M 16 x 1.5
- Thermoplastic enclosure
- Double-insulated
- Interlock with protection against incorrect locking.
- 130 mm x 90 mm x 30 mm
- 6 Contacts
- Long life
Ordering data
Note (Delivery capacity) | Not available! |
Product type description | AZM 161CC-12/12RKED-110/230 |
Article number (order number) | 101187918 |
EAN (European Article Number) | 4030661357201 |
eCl@ss number, Version 9.0 | 27-27-26-03 |
eCl@ss number, Version 11.0 | 27-27-26-03 |
Approval - Standards
Certificates | cULus CCC EAC |
General data
Standards | BG-GS-ET-19 EN 60947-5-1 |
Coding level according to ISO 14119 | Low |
Active principle | electromechanical |
Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Material of the contacts, electrical | Silver |
General data - Features
Power to unlock | Yes |
Manual release | Yes |
Number of actuating directions | 3 |
Number of auxiliary contacts | 2 |
Number of safety contacts | 4 |
Safety appraisal
Standards | EN ISO 13849-1 |
Mission Time | 20 Year(s) |
Safety appraisal - Safety outputs
B10d Normally-closed contact (NC) | 2,000,000 Operations |
B10d Normally open contact (NO) | 1,000,000 Operations |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Actuating play in direction of actuation | 5.5 mm |
Clamping force in accordance with ISO14119 Fzh | 2,000 N |
Latching force | 30 N |
positive break travel | 10 mm |
Positive break force, minimum | 20 N |
Actuating speed, maximum | 2 m/s |
Mechanical data - Connection technique
Terminal Connector | Cage clamps |
Cable section, minimum | 1 x 0.25 mm² |
Cable section, maximum | 1 x 1.5 mm² |
Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Mechanical data - Dimensions
Length of sensor | 30 mm |
Width of sensor | 130 mm |
Height of sensor | 90 mm |
Ambient conditions
Degree of protection | IP67 to EN 60529 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +60 °C |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 4 kV |
Electrical data
Thermal test current | 6 A |
Rated control voltage | 110 VAC |
Rated control voltage | 230 VDC |
Required rated short-circuit current to EN 60947-5-1 | 1,000 A |
Electrical power consumption, maximum | 10 W |
Switching element | NO contact, NC contact |
Switching principle | Creep circuit element |
Switching frequency | 1,000 /h |
Electrical data - Safety contacts
Voltage, Utilisation category AC15 | 230 VAC |
Current, Utilisation category AC-15 | 4 A |
Voltage, Utilisation category DC13 | 24 VDC |
Current, Utilisation category DC13 | 2.5 A |
Electrical data - Auxiliary contacts
Voltage, Utilisation category AC15 | 230 VAC |
Current, Utilisation category AC-15 | 4 A |
Voltage, Utilisation category DC13 | 24 VDC |
Current, Utilisation category DC13 | 2.5 A |
Other data
Note (applications) | sliding safety guard removable guard hinged safety guard |
Scope of delivery
Included in delivery | Actuators must be ordered separately. |
Notes
Note (Manual release) | For maintenance, installation, etc. For manual release using M5 triangular key, available as accessory Top-side (ordering suffix -ED) or rear-side (ordering suffix -EU) mounting possible |
Note (Emergency exit, Manual release) | A combination of manual release and emergency exit in different mounting directions in only possible for the following variants: -ED/-TU and -TD/-EU |