Бренды по алфавиту:
А Б В Г Д Е Ё Ж З И Й К Л М Н О П Р С Т У Ф Х Ц Ч Ш Щ Ъ Ы Ь Э Ю Я
Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Оплата по безналичному расчету согласно выставленному счету
Самовывоз - бесплатно, от 300руб. до пункта выдачи в Вашем городе, доставка от 500руб. "до двери"
  • Pre-wired cable 7-pole
  • Comfortable diagnostics through sensor LED and electronic signalling output
  • Ex certified
  • Thermoplastic enclosure
  • Electronic contact-free, coded system
  • Ø M18
  • Misaligned actuation possible
  • High repeat accuracy of the switching points
  • Max. length of the sensor chain 200 m
  • Early warning when operating near the limit of the sensor's hysteris range
  • Self-monitoring series-wiring of 16 sensors
  • 2 short-circuit proof PNP safety outputs
  • Explosion protection for ATEX Zones 2 and 22

Ordering data

Product type description

EX-CSS 8-180-2P+D-M-L-3G/D

Article number (order number)

101189302

EAN (European Article Number)

4030661347158

eCl@ss number, Version 9.0

27-27-24-02

eCl@ss number, Version 11.0

27-27-24-02

ETIM number, version 6.0

EC002544

ETIM number, version 7.0

EC002544

Explosion protection

Explosion protection: regulations

EN 60079-0

EN 60079-15

EN 60079-31

Explosion protection zones

22

2

Explosion protection category

3D

3G

Explosion protection designation

D II 3G Ex nA IIC T6 Gc X

D II 3D Ex tc IIIC T70°C Dc X

Manufacturer declaration

ATEX Zone 2 and 22

General data

Active principle

inductive

Housing construction form

Cylinder, thread

Installation conditions (mechanical)

not flush

Sensor topology

Sensor for series wiring

Enclosure material

Glass-fibre, reinforced thermoplastic

Active area

Glass-fibre, reinforced thermoplastic

Material of the nuts

Glass-fibre, reinforced thermoplastic

Gross weight

135 g

Reaction time, maximum

30 ms

Duration of risk, maximum

30 ms

General data - Features

Short circuit detection

Yes

Short-circuit recognition

Yes

Safety functions

Yes

Integral System Diagnostics, status

Yes

Number of semi-conductor outputs with signaling function

1

Number of fail-safe digital outputs

2

Number of Series-wiring of sensors

16

Safety appraisal

Standards

EN ISO 13849-1

IEC 61508

Performance level, up to

e

Control category to EN13849

4

PFH-value

2.50 x 10⁻⁹ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission Time

20 Year(s)

Mechanical data

Hysteresis (Switch distance), maximum

0.7 mm

Repeat accuracy R R

0.2 mm

Impact energy, maximum

2 J

Tightening torque of nuts, maximum

3 Nm

Mechanical data - Switching distances according IEC 60947-5-3

Switch distance

8 mm

Ensured switch distance ON Sao

7 mm

Ensured switch distance OFF Sar

10 mm

Mechanical data - Connection technique

Terminal Connector

Cable

Length of cable

2 m

Terminal connector, Output

7-pole

Wire cross-section

0.25 mm2

Wire cross-section

23 AWG

Mechanical data - Dimensions

ISO thread of the sensor

M18

width across flats

24 BK

Length of sensor

92 mm

Ambient conditions

Degree of protection

IP65

IP67

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+40 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+85 °C

Resistance to vibrations to EN 60068-2-6

10 … 55 Hz, amplitude 1 mm

Restistance to shock

30 g / 11 ms

Protection rating

II

Ambient conditions - Insulation value

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution to VDE 0100

3

Electrical data

Voltage type

DC (direct current)

Operating voltage, minimum

20.4 VDC

Operating voltage, maximum

26.4 VDC

No-load supply current I0

50 mA

Rated operating voltage

24 VDC

Operating current

1,000 mA

500 mA

Switching frequency, approx.

3 Hz

Electrical data - Fail-safe digital outputs

Versions

p-type

Voltage drop Ud, maximum

0.5 V

Current leakage Ir

0.5 mA

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

0.5 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

0.5 A

Electrical data - Digital Output

Versions

p-type

Electrical data - Diagnostic output

Voltage drop Ud, maximum

4 V

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

0.05 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

0.05 A

Status indication

Note (LED switching conditions display)

Multi-coloured LED: Green, Red, Yellow

Pin assignment

PIN 1

A1 Ue Brown

PIN 2

Y2 Safety output 2 red

PIN 3

A2 GND Blue

PIN 4

Y1 Safety output 1 Black

PIN 5

X1 Safety input 1 violet

PIN 6

X2 Safety input 2 White

PIN 7

Signalling output Grey

Scope of delivery

Included in delivery

Actuators must be ordered separately.

Delivery scope of Mounting material

2x nuts M18 x 1

Accessory

Recommendation (actuator)

CST 180-1

CST 180-2

Notes

Note (General)

Series-wiring of sensors: 16 safety sensors can be switched in series with self-monitoring. In this case, the dual-channel output of a sensor is switched to/inserted into the input of the next sensor. This does not affect the category 4 in accordance with EN ISO 13849-1.

The voltage drop over a long sensor chain should be taken into account when planning cable routing. Operating voltage, cross-section and length of the cable, temperature, number of sensors connected, but also the input load of the control monitor all affect the voltage drop over the sensor chain.

Наш менеджер свяжется с вами в ближайшее время