- 1 Cable entry M 20 x 1.5
- Thermoplastic enclosure
- one-side operation / wire up to 10 m long
- Position indicator
- Large wiring compartment
- Twisting of towing eye not possible
- One tension force for cable lengths up to 10 m
Ordering data
Product type description | TQ 700-20 |
Article number (order number) | 101192481 |
EAN (European Article Number) | 4030661352695 |
eCl@ss number, Version 9.0 | 27-27-06-07 |
eCl@ss number, Version 11.0 | 27-27-06-07 |
ETIM number, version 6.0 | EC002033 |
Approval - Standards
Certificates | TÜV EAC |
General data
Standards | IEC/EN 60947-5-1 |
Enclosure material | Glass-fibre, thermoplastic |
Material of the contacts, electrical | Silver |
Material of the cover | Glass-fibre, thermoplastic |
Length of the wire, maximum | 10 m |
Gross weight | 205 g |
General data - Features
Number of shutters | 2 |
Safety appraisal
Standards | EN ISO 13849-1 |
Mission Time | 20 Year(s) |
Safety appraisal - Safety outputs
B10d Normally open contact (NO) | 100,000 Operations |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Mechanical data - Connection technique
Terminal Connector | Screw connection |
Cable section, minimum | 0.75 mm² |
Cable section, maximum | 2.5 mm² |
Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Mechanical data - Dimensions
Width | 40.5 mm |
Height | 160 mm |
Depth | 42.2 mm |
Ambient conditions
Degree of protection | IP67 to EN 60529 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +70 °C |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 500 V |
Rated impulse withstand voltage Uimp | 6 kV |
Electrical data
Thermal test current | 10 A |
Utilisation category AC-15 | 230 VAC |
Utilisation category AC-15 | 4 A |
Utilisation category DC-13 | 24 VDC |
Utilisation category DC-13 | 4 A |
Switching element | Normally open contact (NO) |
Switching principle | Creep circuit element |
Notes
Note (General) | Recommended cable lengths for pull-wire Emergency-Stop switches in relation to the range of ambient temperature. As the thimbles are subject to deformation in case of wire pull, the wire should be pulled several times after fitting. After that, the wire must be re-tensioned using the eyebolt or the tensioner. At 2 m ... 5 m distance intermediate wire supports are required, see accessories |