- Individual contact outlet
- Explosion protection for ATEX Zones 2 and 22
- Thermoplastic enclosure
- 88 mm x 25 mm x 13 mm
- Concealed mounting possible
- Insensitive to transverse misalignment
- no mechanical wear
Ordering data
Product type description | EX-BNS 33-02ZG-2187-3G/D 5,0M |
Article number (order number) | 101192970 |
EAN (European Article Number) | 4030661354415 |
eCl@ss number, Version 9.0 | 27-27-24-02 |
eCl@ss number, Version 11.0 | 27-27-24-02 |
ETIM number, version 6.0 | EC002544 |
ETIM number, version 7.0 | EC002544 |
Explosion protection
Explosion protection: regulations | EN 13463-1 EN 13463-5 EN 60079-0 EN 60079-15 EN 60079-31 IEC 60947-5-3 |
Explosion protection zones | 22 2 |
Explosion protection category | 3D 3G |
Explosion protection designation | D II 3G Ex nC IIC T6 Gc X D II 3D Ex tc IIIC T80°C Dc X |
Manufacturer declaration | ATEX Zone 2 and 22 |
General data
Housing construction form | Block |
Installation conditions (mechanical) | not flush |
Enclosure material | Glass-fibre, reinforced thermoplastic |
Gross weight | 202.5 g |
General data - Features
Short circuit detection | Yes |
Short-circuit recognition | Yes |
Integral System Diagnostics, status | Yes |
Prerequisite evaluation unit | Yes |
Number of openers | 2 |
Safety appraisal
Standards | EN ISO 13849-1 |
Mission Time | 20 Year(s) |
Safety appraisal - Safety outputs
B10d Normally-closed contact (NC) | 25,000,000 Operations |
Mechanical data
Active area | lateral |
Actuating element | Magnet |
Repeat accuracy R | ≤ 0.1 x Sao |
Impact energy, maximum | 2 J |
Direction of motion | Head-on to the active surface |
Mechanical data - Switching distances according IEC 60947-5-3
Ensured switch distance ON Sao | 5 mm |
Ensured switch distance OFF Sar | 15 mm |
Mechanical data - Connection technique
Terminal Connector | Cable |
Length of cable | 5 m |
Wire cross-section | 0.25 mm2 |
Wire cross-section | 23 AWG |
Material of the Cable mantle | PVC |
Mechanical data - Dimensions
Length of sensor | 13 mm |
Width of sensor | 88 mm |
Height of sensor | 25 mm |
Ambient conditions
Degree of protection | IP67 |
Resistance to vibrations to EN 60068-2-6 | 10 … 55 Hz, amplitude 1 mm |
Restistance to shock | 30 g / 11 ms |
Electrical data
Voltage type | DC (direct current) |
Switching voltage, maximum | 24 VDC |
Switching current, maximum | 0.01 A |
Switching capacity, maximum | 0.2 W |
Switching frequency, maximum | 5 Hz |
Electrical data - Digital Output
Versions | Miscellaneous, Reed contacts |
Status indication
Note (Integral System Diagnostics, status ) | The LED is illuminated when the guard door is open. |
Scope of delivery
Included in delivery | Actuators must be ordered separately. |
Accessory
Recommendation (actuator) | EX-BPS 33-3G/D |
Recommended safety switchgear | SRB-E-301ST SRB-E-201LC |
Notes
Note (General) | Contact symbols shown for the closed condition of the guard device. The contact configuration for versions with or without LED is identical. |