  • Metal enclosure
  • Good resistance to oil and petroleum spirit
  • 66,7 mm x 76 mm x 38 mm
  • Actuator heads can be repositioned by 4 x 90°
  • Including Ex-certified screwed cable gland and screw plug
  • Mounting details to EN 50041
  • 3 cable entries M 20 x 1.5
  • Ex certified

Ordering data

Product type description

EX-TR 355-12Z-3G/D

Article number (order number)

101205164

EAN (European Article Number)

4030661370798

eCl@ss number, Version 9.0

27-27-26-01

eCl@ss number, Version 11.0

27-27-26-01

ETIM number, version 6.0

EC000030

ETIM number, version 7.0

EC000030

Approval - Standards

Certificates

cULus

Explosion protection

Explosion protection: regulations

EN 60079-15

EN 60079-31

IEC 60079-0

Explosion protection zones

22

2

Explosion protection category

3D

3G

Explosion protection designation

D II 3G Ex nC IIC T5 Gc X

D II 3D Ex tc IIIC T90°C Dc X

Manufacturer declaration

ATEX Zone 2 and 22

General data

Standards

IEC 60947-5-1

BG-GS-ET-15

Housing construction form

Norm construction design

Actuator type to DIN EN 50041

C

Enclosure material

Light alloy die-casting

Enclosure coating material

painted

Material of the contacts, electrical

Silver

Gross weight

295 g

General data - Features

Safety functions

Yes

Number of auxiliary contacts

1

Number of safety contacts

2

Safety appraisal

Standards

EN ISO 13849-1

Mission Time

20 Year(s)

Safety appraisal - Safety outputs

B10d Normally-closed contact (NC)

20,000,000 Operations

Mechanical data

Actuating element

Roller plunger

Mechanical life, minimum

30,000,000 Operations

Impact energy, maximum

1 J

Actuating force, minimum

17 N

Actuating speed, maximum

0.5 m/s

Note (Actuating speed)

Actuating speed with actuating angle 30° to switch axis

Note (Switchover time)

Switchover time in accordance with actuating speed

Mechanical data - Connection technique

Terminal Connector

Screw connection

Cable cross-section of the cable glands, minimum

7 mm

Cable cross-section of the cable glands, maximum

12 mm

Cable section, minimum

0.75 mm²

Cable section, maximum

2.5 mm²

Note (Cable section)

All indications about the cable section are including the conductor ferrules.

Wire cross-section

13 AWG

Mechanical data - Dimensions

Length of sensor

38 mm

Width of sensor

40.5 mm

Height of sensor

116.6 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature, minimum

-20 °C

Ambient temperature, maximum

+60 °C

Ambient conditions - Insulation value

Rated insulation voltage Ui

250 V

Rated impulse withstand voltage Uimp

4 kV

Electrical data

Thermal test current

10 A

Utilisation category AC-15

230 VAC

Utilisation category AC-15

4 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

1 A

Switching element

NO contact, NC contact

Switching principle

Slow action

Bounce duration, maximum

2 ms

Switching frequency

5,000 /h

Наш менеджер свяжется с вами в ближайшее время