- NOTICE: Not available!
- miniature body
- Safety type 4 in accordance with IEC 61496-1
- Resolution 30 mm
- Protection field height from 236 mm … 1804 mm
Ordering data
Note (Delivery capacity) | Not available! |
Product type description | SLC 430-E/R0908-30-RF-SYS |
Article number (order number) | 101207677 |
eCl@ss number, Version 9.0 | 27-27-27-04 |
eCl@ss number, Version 11.0 | 27-27-27-04 |
General data
Standards | IEC/EN 61496-1/-2 |
Enclosure material | Aluminium |
Gross weight | 1,650 g |
Reaction time, maximum | 50 ms |
General data - Features
Restart interlock (manual reset) | Yes |
Beam coding available | Yes |
Integral System Diagnostics, status | Yes |
Integral System Diagnostics | Yes |
Number of beams | 32 |
Number of safety contacts | 2 |
Safety appraisal
Standards | EN ISO 13849-1 IEC 61508 | |
Performance level, up to | e | |
Control category to EN13849 | 4 | |
PFH-value | 1.26 x 10⁻⁸ /h | |
| 3 | |
Mission Time | 20 Year(s) |
Mechanical data
Detection ability for test bodies at v = 1.6 m/s | 30 mm |
Height of the protection field | 908 mm |
Range, protection field, minimum | 200 mm |
Range, protection field, maximum | 3,500 mm |
Wave length of the sensor | 880 nm |
Mechanical data - Connection technique
Terminal Connector | Connector |
Length of cable | 5 m |
Terminal connector, Recipient | Cable with connector plug M8, 4-pole |
Terminal, Connector, Transmitter | Cable with connector plug M8, 4-pole |
Length of the connectable cable, maximum | 100 m |
Mechanical data - Dimensions
Length of sensor | 20 mm |
Width of sensor | 12 mm |
Height of sensor | 1,140 mm |
Ambient conditions
Degree of protection | IP65 to EN 60529 |
Ambient temperature, minimum | +0 °C |
Ambient temperature, maximum | +50 °C |
Storage and transport temperature, minimum | -10 °C |
Storage and transport temperature, maximum | +70 °C |
Protection rating | III |
Electrical data
Voltage type | AC (alternating current) DC (direct current) |
Switching voltage OSSD, HIGH signal | 24 V |
Electrical power consumption of the receiver | 4 W |
Electrical power consumption of the transmitter | 4 W |
Electrical data - Fail-safe digital outputs
Output current, (fail-safe output), maximum | 4 A |
Versions | p-type |
Scope of delivery
Included in delivery | Emitter + receiver, mounting angle |
Accessory
Recommended safety switchgear | NSR-0605 |
Notes
Note (General) | Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA. |