Бренды по алфавиту:
А Б В Г Д Е Ё Ж З И Й К Л М Н О П Р С Т У Ф Х Ц Ч Ш Щ Ъ Ы Ь Э Ю Я
Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Оплата по безналичному расчету согласно выставленному счету
Самовывоз - бесплатно, от 300руб. до пункта выдачи в Вашем городе, доставка от 500руб. "до двери"
  • 1 x connector plug M12, 8-pole
  • Actuation from side
  • with On-site acknowledgment
  • NOTICE: Not available! (Replacement: RSS 36 I)
  • Thermoplastic enclosure
  • Electronic contact-free, coded system
  • Tampering protection by paired coding of sensor and actuator
  • Misaligned actuation possible
  • High repeat accuracy of the switching points
  • Max. length of the sensor chain 200 m
  • 2 short-circuit proof PNP safety outputs
  • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet

Ordering data

Note (Delivery capacity)

Not available!

Product type description

CSP 11-34F2-D-M-ST

Article number (order number)

101208005

EAN (European Article Number)

4030661382029

eCl@ss number, Version 9.0

27-27-24-03

eCl@ss number, Version 11.0

27-27-24-03

Approval - Standards

Certificates

cULus

EAC

General data

Standards

IEC 61508

IEC 60947-5-3

EN ISO 13849-1

Active principle

inductive

Housing construction form

Block

Installation conditions (mechanical)

not flush

Sensor topology

Sensor for series wiring

Enclosure material

Glass-fibre, reinforced thermoplastic

Active area

Glass-fibre, reinforced thermoplastic

Gross weight

140.5 g

Reaction time, maximum

30 ms

Duration of risk, maximum

60 ms

General data - Features

Diagnostic output

Yes

Short circuit detection

Yes

Short-circuit recognition

Yes

Safety functions

Yes

Cascadable

Yes

Input for reset pushbutton, with edge monitoring

Yes

Input for enabling pushbutton, suitable for automatic start

Yes

On-site acknowledgment

Yes

Integral System Diagnostics, status

Yes

Number of LEDs

3

Number of semi-conductor outputs with signaling function

1

Number of fail-safe digital outputs

2

Number of Series-wiring of sensors

31

Safety appraisal

Standards

IEC 60947-5-3

IEC 61508

Performance level, up to

e

Control category to EN13849

4

PFH-value

3.60 x 10⁻⁹ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission Time

20 Year(s)

Mechanical data

Actuating panels

lateral

Active area

lateral

Hysteresis (Switch distance), maximum

1.5 mm

Repeat accuracy R R

0.5 mm

Note (Repeat accuracy R)

Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 30 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 8 mm.

Mechanical data - Switching distances according IEC 60947-5-3

Switch distance

11 mm

Ensured switch distance ON Sao

8 mm

Ensured switch distance OFF Sar

15 mm

Mechanical data - Connection technique

Terminal Connector

Connector plug M12, 8-pole

Note

The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current

Mechanical data - Dimensions

Length of sensor

27 mm

Width of sensor

35 mm

Height of sensor

108.2 mm

Ambient conditions

Degree of protection

IP65 to EN 60529

IP67 to EN 60529

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+70 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+85 °C

Resistance to vibrations to EN 60068-2-6

10 … 55 Hz, amplitude 1 mm

Restistance to shock

30 g / 11 ms

Protection rating

II

Ambient conditions - Insulation value

Rated insulation voltage Ui

32 VAC/DC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution to VDE 0100

3

Electrical data

Voltage type

DC (direct current)

No-load supply current I0

100 mA

Rated operating voltage, minimum

20.4 VDC

Rated operating voltage, maximum

26.4 VDC

Operating current

600 mA

Required rated short-circuit current to EN 60947-5-1

100 A

Utilisation category DC-12

24 VDC

Utilisation category DC-12

0.05 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

0.05 A

Switching frequency, approx.

3 Hz

Electrical data - Fail-safe digital outputs

Rated operating current (safety outputs)

250 mA

Output current, (fail-safe output), maximum

0.25 A

Versions

p-type

Voltage drop Ud, maximum

0.5 V

Current leakage Ir

0.5 mA

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

0.25 A

Voltage, Utilisation category DC13

24 VDC

Electrical data - Digital Output

Versions

p-type

Electrical data - Diagnostic output

Operating current

50 mA

Voltage drop Ud, maximum

5 V

Voltage, Utilisation category DC12

24 VDC

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation

IEC 61000-6-4

EMC rating

IEC 61000-6-2

Pin assignment

PIN 1

1A1 Ue: (1)

PIN 2

X1 Safety input 1

PIN 3

A2 GND

PIN 4

Y1 Safety output 1

PIN 5

OUT Diagnostic output OUT

PIN 6

X2 Safety input 2

PIN 7

Y2 Safety output 2

PIN 8

IN On-site acknowledgment

Scope of delivery

Included in delivery

Actuators must be ordered separately.

Accessory

Recommendation (actuator)

CSP 34-S-1

Recommended safety switchgear

PROTECT PSC1

SRB-E-301ST

SRB-E-201LC

Notes

Note (General)

When safety gate monitoring by the safety sensor CSP 34F2 is required, an acknowledge button should be positioned so that the danger area can be viewed. When the button is pushed, a 24 VDC signal is generated at the reset input of the CSP 34F2.

If the gate is closed the safety outputs are released with the negative signal edge. After the gate is opened it needs to be acknowledge before it can be released again.

On-site acknowledgment

Наш менеджер свяжется с вами в ближайшее время