Самовывоз - бесплатно, от 300руб. до пункта выдачи в Вашем городе, доставка от 500руб. "до двери"
  • UNIVERSAL Gateway for the series-wiring of the diagnostic signals of safety

    switchgear with integrated SD interface.
  • Comprehensive volumes of status and diagnostic data of the SD devices are transmitted to the control system through the field bus interface.
  • Series-wiring of the diagnostic lines of max. 31 safety switchgear
  • Series-wiring of different devices possible
  • Reduced wiring efforts and costs as a result of the series-wiring of the safety channels and the diagnostic cables in the field.
  • Automatic addressing of the safety switchgear in the SD interface

Ordering data

Note (Delivery capacity)

Not available!

Product type description

SD-I-U-CAN

Article number (order number)

101209433

EAN (European Article Number)

4030661448862

General data

Gross weight

180 g

General data - Features

Integral System Diagnostics, status

Yes

Number of LEDs

1

Mechanical data

Mounting

Snaps onto standard DIN rail to EN 60715

Mechanical data - Connection technique

Terminal Connector

Cage clamps

Mechanical data - Dimensions

Width

50 mm

Height

100 mm

Depth

80 mm

Ambient conditions

Degree of protection of the enclosure

IP20

Ambient temperature, minimum

+0 °C

Ambient temperature, maximum

+55 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+75 °C

Relative humidity, minimum

30 %

Relative humidity, maximum

85 %

Note (Relative humidity)

non-condensing

Resistance to vibrations to EN 60068-2-6

10 ... 57 Hz, Amplitude 0.35 mm

57 ... 150 Hz, with 5 g

Restistance to shock

10 g

Ambient conditions - Insulation value

Rated insulation voltage Ui

32 V

Rated impulse withstand voltage Uimp

0.5 kV

Overvoltage category

II

Degree of pollution to VDE 0110

2

Electrical data

Rated operating voltage

24 VDC, - 15 % / + 20 % (stabilised PELV)

Operating current

500 mA

Electrical data - Communication protocols

Field bus

CANopen

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation

IEC 61000-6-4 (2002)

Other data

Note (applications)

Safety sensor

Guard system