  • Actuator monitored
  • Connector M12, 8-pole
  • Power to lock
  • serial diagnostic output
  • Automatic latching
  • Solenoid interlocks (for the protection of man) with innovating and unique operating principle
  • 40 mm x 179 mm x 40 mm
  • Electronic contact-free, coded system
  • Thermoplastic enclosure
  • Max. length of the sensor chain 200 m
  • 3 LEDs to show operating conditions
  • Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
  • Intelligent diagnosis
  • Self-monitoring series-wiring
  • Patented

Ordering data

Product type description

MZM 100 B ST2-SD2PRE-A

Article number (order number)

101211156

EAN (European Article Number)

4030661389424

eCl@ss number, Version 9.0

27-27-26-03

eCl@ss number, Version 11.0

27-27-26-03

Approval - Standards

Certificates

TÜV

cULus

EAC

General data

Standards

IEC 61508

EN 60947-5-3

EN ISO 13849-1

EN ISO 14119

general information

Universal coding

Coding level according to ISO 14119

Low

Active principle

inductive

Enclosure material

Glass-fibre, reinforced thermoplastic

Gross weight

620 g

Time to readiness, maximum

4,000 ms

Reaction time, maximum

150 ms

Duration of risk, maximum

150 ms

General data - Features

Power to lock

Yes

Actuator monitored

Yes

Serial diagnostics

Yes

Latching

Yes

Short circuit detection

Yes

Short-circuit recognition

Yes

Series-wiring

Yes

Safety functions

Yes

Integral System Diagnostics, status

Yes

Number of safety contacts

2

Number of Series-wiring of sensors

31

Safety appraisal

Standards

IEC 61508

EN ISO 13849-1

Safety appraisal - Interlocking

Performance level, up to

e

Control category

4

PFH-value

3.54 x 10⁻⁹ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission Time

20 Year(s)

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Note (Mechanical lifetime)

Actuating speed < 0.5=''>

Operations for door weights ≤ 5 kg

Clamping force, typically

750 N

Clamping force, guaranteed

500 N

Latching force, minimum

30 N

Latching force, maximum

100 N

Mechanical data - Connection technique

Terminal Connector

Connector M12, 8-pole

Mechanical data - Dimensions

Length of sensor

40 mm

Width of sensor

40 mm

Height of sensor

179 mm

Ambient conditions

Degree of protection

IP65 to EN 60529

IP67 to EN 60529

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+55 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+70 °C

Relative humidity, minimum

30 %

Relative humidity, maximum

95 %

Note (Relative humidity)

non-condensing

non-icing

Resistance to vibrations to EN 60068-2-6

10 … 150 Hz, amplitude 0.35 mm

Restistance to shock

30 g / 11 ms

Protection rating

III

Ambient conditions - Insulation value

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution to VDE 0100

3

Electrical data

Operating voltage, minimum

20.4 VDC

Operating voltage, maximum

26.4 VDC

No-load supply current I0

600 mA

Operating current

50 mA

Required rated short-circuit current to EN 60947-5-1

100 A

Note

Cable length and cable section alter the voltage drop depending on the output current

Switching frequency, maximum

1 Hz

Electrical data - Solenoid control

Switching thresholds

-3 V … 5 V (Low)

15 V … 30 V (High)

Classification ZVEI CB24I, Sink

C0

Classification ZVEI CB24I, Source

C1

C2

C3

Electrical data - Fail-safe digital inputs

Switching thresholds

−3 V … 5 V (Low)

15 V … 30 V (High)

Classification ZVEI CB24I, Sink

C1

Classification ZVEI CB24I, Source

C1

C2

C3

Electrical data - Fail-safe digital outputs

Rated operating current (safety outputs)

250 mA

Voltage drop Ud, maximum

1 V

Current leakage Ir

0.5 mA

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

0.25 A

Classification ZVEI CB24I, Source

C1

Classification ZVEI CB24I, Sink

C1

Electrical data - Diagnostic output

Voltage drop Ud, maximum

2 V

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

0.05 A

Status indication

Note (LED switching conditions display)

Operating condition: LED green

Error / functional defect: LED red

Supply voltage UB: LED green

Pin assignment

PIN 1

A1 Supply voltage UB

PIN 2

X1 Safety input 1

PIN 3

A2 GND

PIN 4

Y1 Safety output 1

PIN 5

OUT serial diagnostic output

PIN 6

X2 Safety input 2

PIN 7

Y2 Safety output 2

PIN 8

IN serial diagnostic input

Scope of delivery

Included in delivery

Actuators must be ordered separately.

Accessory

Recommendation (actuator)

MZM 100-B1.1

Notes

Note (General)

As long as the actuating unit is applied to the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened.