- Metal enclosure
- Good resistance to oil and petroleum spirit
- 66,7 mm x 76 mm x 38 mm
- Actuator heads can be repositioned by 4 x 90°
- Including Ex-certified screwed cable gland and screw plug
- Mounting details to EN 50041
- 3 cable entries M 20 x 1.5
- Ex certified
- only for positioning tasks
Ordering data
Note (Delivery capacity) | Not available! |
Product type description | EX-T4V10H335-20Y |
Article number (order number) | 101212060 |
EAN (European Article Number) | 4030661448701 |
Approval - Standards
Certificates | cULus CCC CCC EX DEKRA DEKRA EX |
Explosion protection
Explosion protection: regulations | EN 60079-15 EN 60079-31 IEC 60079-0 |
Explosion protection zones | 22 2 |
Explosion protection category | 3D 3G |
Explosion protection designation | D II 3G Ex nC IIC T5 Gc X D II 3D Ex tc IIIC T90°C Dc X |
General data
Standards | BG-GS-ET-15 IEC 60947-5-1 |
Housing construction form | Norm construction design |
Enclosure material | Light alloy die-casting |
Enclosure coating material | painted |
Material of the contacts, electrical | Silver |
Lever material | Metal film |
Material of the rod | Plastic |
Gross weight | 400 g |
General data - Features
Number of auxiliary contacts | 2 |
Safety appraisal
Standards | EN ISO 13849-1 |
Mission Time | 20 Year(s) |
Mechanical data
Actuating element | Rod lever |
Mechanical life, minimum | 30,000,000 Operations |
Impact energy, maximum | 1 J |
Actuating speed, maximum | 2.5 m/s |
Note (Actuating speed) | Actuating speed with actuating angle 30° to switch axis |
Note (Switchover time) | Switchover time in accordance with actuating speed |
Actuating torque, minimum | 0.3 Nm |
Mechanical data - Connection technique
Terminal Connector | Screw connection |
Cable cross-section of the cable glands, minimum | 7 mm |
Cable cross-section of the cable glands, maximum | 12 mm |
Cable section, minimum | 0.75 mm² |
Cable section, maximum | 2.5 mm² |
Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Wire cross-section | 13 AWG |
Mechanical data - Dimensions
Length x Width x Height | Height of sensor: 111.5 mm (without rod) |
Length of sensor | 38 mm |
Width of sensor | 40.5 mm |
Ambient conditions
Degree of protection | IP67 |
Ambient temperature, minimum | -20 °C |
Ambient temperature, maximum | +60 °C |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 4 kV |
Electrical data
Thermal test current | 10 A |
Utilisation category AC-15 | 230 VAC |
Utilisation category AC-15 | 4 A |
Utilisation category DC-13 | 24 VDC |
Utilisation category DC-13 | 1 A |
Switching element | Normally open contact (NO) |
Switching principle | Slow action |
Bounce duration, maximum | 3 ms |
Switching frequency | 5,000 /h |
Notes
Note (General) | Switch with 2 NO contacts are not for security tasks |