- Protection class IP67
- Safety type 4 in accordance with IEC 61496-1
- Parameter assignment using external command devices
- Resolution 14 and 30 mm
Ordering data
Note (Delivery capacity) | Not available! |
Product type description | SLC 421-E/R0570-14-RFBC |
Article number (order number) | 101212686 |
EAN (European Article Number) | 4030661397184 |
eCl@ss number, Version 9.0 | 27-27-27-04 |
eCl@ss number, Version 11.0 | 27-27-27-04 |
Approval - Standards
Certificates | cULus EAC |
General data
Standards | IEC/EN 61496-1/-2 |
Enclosure material | Aluminium |
Gross weight | 2,860 g |
Reaction time, maximum | 25 ms |
General data - Features
Clock control possible | Yes |
Restart interlock (manual reset) | Yes |
Contactor control integrated | Yes |
Beam coding available | Yes |
Hide function | Yes |
Integral System Diagnostics, status | Yes |
Integral System Diagnostics | Yes |
Number of beams | 56 |
Number of fail-safe digital outputs | 2 |
Safety appraisal
Standards | EN ISO 13849-1 IEC 60947-5-3 IEC 61508 | |
Performance level, up to | e | |
Control category to EN13849 | 4 | |
PFH-value | 7.42 x 10⁻⁹ /h | |
| 3 | |
Mission Time | 20 Year(s) | |
Safety type in accordance with IEC 61496-1 | 4 |
Mechanical data
Detection ability for test bodies at v = 1.6 m/s | 14 mm |
Height of the protection field | 570 mm |
Range, protection field, minimum | 300 mm |
Range, protection field, maximum | 7,000 mm |
Wave length of the sensor | 880 nm |
Mechanical data - Connection technique
Terminal Connector | Connector |
Terminal connector, Recipient | Connector plug M12, 12-pole |
Terminal, Connector, Transmitter | Connector plug M12, 4-pole |
Length of the connectable cable, maximum | 100 m |
Mechanical data - Dimensions
Diameter of sensor | 49 mm |
Height of sensor | 788 mm |
Ambient conditions
Degree of protection | IP67 to EN 60529 |
Ambient temperature, minimum | -10 °C |
Ambient temperature, maximum | +50 °C |
Storage and transport temperature, minimum | -20 °C |
Storage and transport temperature, maximum | +70 °C |
Protection rating | III |
Electrical data
Voltage type | DC (direct current) |
Switching voltage OSSD, HIGH signal | 24 V |
Electrical power consumption of the receiver | 8 W |
Electrical power consumption of the transmitter | 4 W |
Wiring / Connector of external control unit | Connector plug M8, 6-pole |
Electrical data - Fail-safe digital outputs
Output current, (fail-safe output), maximum | 0.5 A |
Versions | p-type |
Scope of delivery
Included in delivery | Emitter + receiver, mounting angle |
Accessory
Recommended safety switchgear | SCR 211 |
Notes
Note (General) | Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA. |
Note (Clock control) | 1 cycle or 2 cycles |