Бренды по алфавиту:
А Б В Г Д Е Ё Ж З И Й К Л М Н О П Р С Т У Ф Х Ц Ч Ш Щ Ъ Ы Ь Э Ю Я
Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Оплата по безналичному расчету согласно выставленному счету
Самовывоз - бесплатно, от 300руб. до пункта выдачи в Вашем городе, доставка от 500руб. "до двери"
  • serial diagnostic output
  • Thermoplastic enclosure
  • Max. 31 sensors can be wired in series.
  • Connector M12, 8-pole
  • Ø M30
  • High repeat accuracy of the switching points
  • Max. length of the sensor chain 200 m
  • 2 short-circuit proof PNP safety outputs
  • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
  • Safety sensor can also be installed behind V4A covers.

Ordering data

Product type description

CSS 11-300-SD-M-ST

Article number (order number)

101213905

EAN (European Article Number)

4030661405667

eCl@ss number, Version 9.0

27-27-24-03

eCl@ss number, Version 11.0

27-27-24-03

Approval - Standards

Certificates

TÜV

cULus

EAC

General data

Standards

IEC 60947-5-3

EN ISO 13849-1

Active principle

inductive

Housing construction form

Cylinder, thread

Installation conditions (mechanical)

not flush

Sensor topology

Sensor for series wiring

Enclosure material

Plastic

Active area

Plastic

Gross weight

135 g

Reaction time, maximum

60 ms

Duration of risk, maximum

60 ms

General data - Features

Serial diagnostics

Yes

Diagnostic output

Yes

Short circuit detection

Yes

Short-circuit recognition

Yes

Safety functions

Yes

Cascadable

Yes

Integral System Diagnostics, status

Yes

Number of LEDs

2

Number of semi-conductor outputs with signaling function

1

Number of fail-safe digital outputs

2

Number of Series-wiring of sensors

31

Safety appraisal

Standards

IEC 60947-5-3

IEC 61508

Performance level, up to

e

Control category to EN13849

4

PFH-value

3.60 x 10⁻⁹ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission Time

20 Year(s)

Mechanical data

Actuating panels

Actuation from top

Active area

front side

Hysteresis (Switch distance), maximum

2 mm

Repeat accuracy R R

1 mm

Mechanical data - Switching distances according IEC 60947-5-3

Switch distance

11 mm

Ensured switch distance ON Sao

8 mm

Ensured switch distance OFF Sar

15 mm

Mechanical data - Connection technique

Note

The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current

Mechanical data - Dimensions

ISO thread of the sensor

M30

Length of sensor

99.5 mm

Ambient conditions

Degree of protection

IP69 to EN 60529

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+65 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+85 °C

Resistance to vibrations to EN 60068-2-6

10 … 55 Hz, amplitude 1 mm

Restistance to shock

30 g / 11 ms

Protection rating

II

Ambient conditions - Insulation value

Rated insulation voltage Ui

32 VAC/DC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution to VDE 0100

3

Electrical data

Voltage type

DC (direct current)

No-load supply current I0

100 mA

Rated operating voltage, minimum

20.4 VDC

Rated operating voltage, maximum

26.4 VDC

Operating current

600 mA

Required rated short-circuit current to EN 60947-5-1

100 A

Switching frequency, approx.

3 Hz

Electrical data - Fail-safe digital outputs

Rated operating current (safety outputs)

250 mA

Output current, (fail-safe output), maximum

0.25 A

Versions

p-type

Voltage drop Ud, maximum

0.5 V

Current leakage Ir

0.5 mA

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

0.25 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

0.25 A

Electrical data - Diagnostic output

Operating current

150 mA

Versions

p-type

Voltage drop Ud, maximum

5 V

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation

IEC 61000-6-4

EMC rating

IEC 61000-6-2

Pin assignment

PIN 1

1A1 Ue: (1)

PIN 2

X1 Safety input 1

PIN 3

A2 GND

PIN 4

Y1 Safety output 1

PIN 5

SD serial diagnostic output

PIN 6

X2 Safety input 2

PIN 7

Y2 Safety output 2

PIN 8

IN serial diagnostic input

Scope of delivery

Included in delivery

Actuators must be ordered separately.

Delivery scope of Mounting material

2x Mounting accessories Nuts M30

Accessory

Recommendation (actuator)

CST 30S-1

Recommended safety switchgear

PROTECT PSC1

SRB-E-301ST

SRB-E-201LC

Notes

Note (General)

Evaluation requirements: The switch-off pauses of 250 µs – 1500 µs must be tolerated by the evaluation.

The switch-off time of the safety sensor of 250 μs is additionally extended according the cable length and the capacity of the cable used. Typically a switch off time of 500 μs with 100 m of connection cable is reached.

Наш менеджер свяжется с вами в ближайшее время