- AS-Interface M12 connector
- Metal enclosure
- Wide range of alternative actuators
- Good resistance to oil and petroleum spirit
- 40,5 mm x 96 mm x 38 mm
- Actuator heads can be repositioned by 4 x 90°
- Mounting details to EN 50047
- AS-Interface LED and status display
- Integrated AS-Interface
- Suitable for AS-i Power24
Ordering data
Note (Delivery capacity) | Not available! |
Product type description | TR 335 ST-AS |
Article number (order number) | 101213983 |
EAN (European Article Number) | 4030661404189 |
eCl@ss number, Version 9.0 | 27-27-06-01 |
eCl@ss number, Version 11.0 | 27-27-06-01 |
ETIM number, version 6.0 | EC000030 |
ETIM number, version 7.0 | EC000030 |
Approval - Standards
Certificates | cULus ASi-SaW EAC |
General data
Standards | IEC 61508 EN 60947-5-1 EN 50295 EN ISO 13849-1 |
Housing construction form | Norm construction design |
Actuator type to DIN EN 50041 | C |
Enclosure material | Zink |
Enclosure coating material | painted |
Material of the contacts, electrical | Silver |
Gross weight | 215 g |
General data - Features
Safety functions | Yes |
Integral System Diagnostics, status | Yes |
Number of safety contacts | 2 |
Safety appraisal
Standards | IEC 61508 | |
Performance level, up to | c | |
Control category to EN13849 | 1 | |
PFH-value | 1.14 x 10⁻⁶ /h | |
Note (PFH-value) | up to max. 100,000 switching cycles/year | |
| 1 | |
Mission Time | 20 Year(s) |
Safety appraisal - Fault exclusion
Please note: | Einsetzbar wenn ein Fehlerausschluss für eine gefahrbringende Beschädigung der 1-kanaligen Mechanik zulässig ist und ein ausreichender Manipulationsschutz gewährleistet ist. |
Performance Level, up to | d |
Control category to EN13849 | 3 |
PFH-value | 1.01 x 10⁻⁷ /h |
Note (PFH-value) | up to max. 100,000 switching cycles/year |
Safety Integrity Level (SIL), suitable for applications in | 2 |
Mission time | 20 Year(s) |
Mechanical data
Actuating element | Roller plunger |
Mechanical life, minimum | 1,000,000 Operations |
Actuating speed, maximum | 0.5 m/s |
Note (Actuating speed) | Actuating speed with actuating angle 30° to switch axis |
Mechanical data - Connection technique
Terminal Connector | Connector plug M12, 5-pole, can be rotated |
Material of the connector (electrical) | Metal film |
Mechanical data - Dimensions
Length of sensor | 38 mm |
Width of sensor | 40.5 mm |
Height of sensor | 136.6 mm |
Ambient conditions
Degree of protection | IP67 to EN 60529 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +60 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +85 °C |
Relative humidity, minimum | 30 % |
Relative humidity, maximum | 95 % |
Note (Relative humidity) | non-condensing non-icing |
Resistance to vibrations to EN 60068-2-6 | 10 … 150 Hz, amplitude 0.35 / 5 g |
Restistance to shock | 30 g / 11 ms |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Electrical data
Operating Current | 50 mA |
Thermal test current | 10 A |
Utilisation category AC-15 | 230 VAC |
Utilisation category AC-15 | 4 A |
Utilisation category DC-13 | 24 VDC |
Utilisation category DC-13 | 1 A |
Switching element | Opener (NC) |
Switching principle | Creep circuit element |
Switching frequency | 5,000 /h |
Electrical data - AS Interface
AS-i Operating voltage, minimum | 18 VDC |
AS-i Operating voltage AS-i maximum | 31.6 VDC |
Note (AS-i Operating voltage) | Protection against polarity reversal |
Electrical data - AS-Interface specification
AS-i Version | V 3.0 |
AS-i Profile | S-0.B.F.F |
AS-i Input, Channel 1 | Data bits DI 0 / DI 1 = dynamic code transmission |
AS-i Input, Channel 2 | Data bits DI 2 / DI 3 = dynamic code transmission |
AS-i Outputs, DO 0 … DO 3 | No Function |
AS-i Parameter bits, P0 | Channel 2 switched |
AS-i Parameter bits, P1 ... P3 | No function |
AS-i Input module address | 0 |
Note (AS-i Input module address) | Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |
Status indication
Note (LED switching conditions display) | (1) LED yellow: Channel 1 / AS-i SaW Bit 0.1 (2) LED green-red (AS-i Duo LED):Supply voltage / Communication error / Slave address = 0 (3) LED yellow: Channel 2 / AS-i SaW Bit 2.3 |
Pin assignment
PIN 1 | AS-Interface + |
PIN 2 | n.c. |
PIN 3 | AS-Interface - |
PIN 4 | n.c. |
PIN 5 | Functional earth connection |