  • Universal coding with RFID technology
  • 1 x connector socket M12, 8-pole
  • Actuation from side
  • Max. 31 sensors can be wired in series.
  • serial diagnostic output
  • Thermoplastic enclosure
  • RFID-technology for needs-based protection against tampering
  • Misaligned actuation possible
  • 27 mm x 108.2 mm x 35 mm
  • High repeat accuracy of the switching points
  • 2 short-circuit proof PNP safety outputs
  • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet

Ordering data

Product type description

RSS 36-SD-ST

Article number (order number)

101214772

EAN (European Article Number)

4030661413402

eCl@ss number, Version 9.0

27-27-24-03

eCl@ss number, Version 11.0

27-27-24-03

Approval - Standards

Certificates

TÜV

cULus

ECOLAB

EAC

FCC

IC

General data

Standards

IEC 60947-5-3

general information

Universal coding

Coding level according to ISO 14119

Low

Active principle

RFID

Housing construction form

Block

Installation conditions (mechanical)

not flush

Sensor topology

Sensor for series wiring

Enclosure material

Plastic, glass-fibre reinforced thermoplastic, self-extinguishing

Active area

Glass-fibre, reinforced thermoplastic

Gross weight

85 g

Time to readiness, maximum

2,000 ms

Reaction time, maximum

100 ms

Duration of risk, maximum

200 ms

General data - Features

Serial diagnostics

Yes

Diagnostic output

Yes

Short circuit detection

Yes

Short-circuit recognition

Yes

Safety functions

Yes

Cascadable

Yes

Integral System Diagnostics, status

Yes

Number of LEDs

3

Number of semi-conductor outputs with signaling function

1

Number of fail-safe digital outputs

2

Number of Series-wiring of sensors

31

Safety appraisal

Standards

EN ISO 13849-1

IEC 60947-5-3

EN 62061

IEC 61508

Performance level, up to

e

Control category to EN13849

4

PFH-value

2.70 x 10⁻¹⁰ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission Time

20 Year(s)

Mechanical data

Actuating panels

lateral

Active area

lateral

Hysteresis (Switch distance), maximum

2 mm

Repeat accuracy R R

0.5 mm

Note (Repeat accuracy R)

Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle). Minimum clearance between two sensor systems 100 mm.

Mounting

A screw length of 25 mm is sufficient for sensor mounting and for side mounting of the actuators. 30 mm long screws are recommended when the actuator is mounted upright and/or when the sealing discs are used.

Mechanical data - Switching distances according IEC 60947-5-3

Switch distance

12 mm

Ensured switch distance ON Sao

10 mm

Ensured switch distance OFF Sar

20 mm

Mechanical data - Connection technique

Terminal Connector

Connector M12, 8-pole

Note

The cable section of the interconnecting cable must be observed! Cable length and cable section alter the voltage drop depending on the output current

Mechanical data - Dimensions

Length of sensor

22 mm

Width of sensor

106.3 mm

Height of sensor

25 mm

Ambient conditions

Degree of protection

IP65 to EN 60529

IP67 to EN 60529

IP69 to EN 60529

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+70 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+85 °C

Material temperature resistance of the cable (in motion), minimum

-10 °C

Material temperature resistance of the cable (at rest), minimum

-30 °C

Material temperature resistance (long-term), maximum

+105 °C

Resistance to vibrations to EN 60068-2-6

10 … 55 Hz, amplitude 1 mm

Restistance to shock

30 g / 11 ms

Protection rating

III

Ambient conditions - Insulation value

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution to VDE 0100

3

Electrical data

Voltage type

DC (direct current)

No-load supply current I0

100 mA

Rated operating voltage

24 VDC −15 % / +10 %

Rated operating voltage, minimum

20.4 VDC

Rated operating voltage, maximum

26.4 VDC

Operating current

600 mA

Required rated short-circuit current to EN 60947-5-1

100 A

Switching frequency, approx.

1 Hz

Electrical data - Fail-safe digital outputs

Rated operating current (safety outputs)

250 mA

Output current, (fail-safe output), maximum

0.25 A

Versions

p-type

Voltage drop Ud, maximum

1 V

Current leakage Ir

0.5 mA

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

0.25 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

0.25 A

Electrical data - Diagnostic output

Operating current

150 mA

Versions

p-type

Voltage drop Ud, maximum

2 V

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation

IEC 61000-6-4

EMC rating

IEC 60947-3

Status indication

Note (LED switching conditions display)

LED yellow: Operating condition

LED green: Supply voltage

LED red: Fault

Pin assignment

PIN 1

A1 Ue Brown

PIN 2

X1 Safety input 1 White

PIN 3

A2 GND Blue

PIN 4

Y1 Safety output 1 Black

PIN 5

serial diagnostic output OUT Grey

PIN 6

X2 Safety input 2 violet

PIN 7

Y2 Safety output 2 red

PIN 8

IN serial diagnostic input Pink

Scope of delivery

Included in delivery

Actuators must be ordered separately.

Accessory

Recommendation (actuator)

RST 36-1

RST 36-1-R

Recommended safety switchgear

PROTECT PSC1

SRB-E-301ST

SRB-E-201LC

Notes

Note (General)

Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 2 ms. Short-circuit recognition by the evaluation is not necessary.