- 2 Contacts
- AS-Interface M12 connector
- Protective shield with wide opening
- Low operating height of pedal
- Integrated AS-Interface
- Suitable for AS-i Power24
Ordering data
Product type description | TFH 232 ST-AS UEDR |
Article number (order number) | 101215189 |
EAN (European Article Number) | 4030661404486 |
eCl@ss number, Version 9.0 | 27-37-12-18 |
eCl@ss number, Version 11.0 | 27-37-12-18 |
ETIM number, version 6.0 | EC001258 |
Approval - Standards
Certificates | cULus ASi-SaW EAC |
General data
Standards | IEC 61508 EN 60947-5-1 EN 50295 EN ISO 13850 EN ISO 13849-1 |
Enclosure material | Aluminium |
Enclosure coating material | powder-coated |
Material of the cover | Aluminium |
Material of the pedal | Glass-fibre, reinforced thermoplastic |
Material of the protective shield | Aluminium |
Colour of the product | White aluminum |
Gross weight | 1,915 g |
General data - Features
Latching | Yes |
Pressure point | Yes |
Overlapping contacts | Yes |
Probing possible | Yes |
Latching | Yes |
Suitable for EMERGENCY-OFF | Yes |
Number of openers | 1 |
Number of shutters | 1 |
Safety appraisal
Standards | IEC 61508 | |
Performance level, up to | c | |
Control category to EN13849 | 1 | |
PFH-value | 1.14 x 10⁻⁶ /h | |
Note (PFH-value) | up to max. 36,500 switching cycles/year | |
| 1 | |
Mission Time | 20 Year(s) |
Mechanical data
Mechanical life, minimum | 200,000 Operations |
Mechanical data - Connection technique
Terminal Connector | Connector plug M12, 5-pole |
Mechanical data - Dimensions
Width | 170 mm |
Height | 189 mm |
Depth | 274 mm |
Ambient conditions
Degree of protection | IP65 to EN 60529 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +60 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +85 °C |
Relative humidity, minimum | 30 % |
Relative humidity, maximum | 95 % |
Note (Relative humidity) | non-condensing non-icing |
Resistance to vibrations to EN 60068-2-6 | 10 … 150 Hz (0.35 mm / 5 g) |
Restistance to shock | 15 g / 11 ms |
Ambient conditions - Insulation value
Overvoltage category | III |
Degree of pollution to VDE 0100 | 3 |
Electrical data
Operating Current | 50 mA |
Switching element | NO contact, NC contact |
Switching frequency | 3,600 /h |
Electrical data - AS Interface
AS-i Operating voltage, minimum | 18 VDC |
AS-i Operating voltage AS-i maximum | 31.6 VDC |
Note (AS-i Operating voltage) | Protection against polarity reversal |
Electrical data - AS-Interface specification
AS-i Version | V 3.0 |
AS-i Profile | S-0.B.F.F |
AS-i, IO-Code | 0x0 |
AS-i, ID-Code | 0xB |
AS-i, ID-Code1 | 0xF |
AS-i, ID-Code2 | 0xF |
AS-i Input, Channel 1 | Data bits DI 0 / DI 1 = dynamic code transmission |
AS-i Input, Channel 2 | Data bits DI 2 / DI 3 = dynamic code transmission |
AS-i Outputs, DO 0 | Solenoid control |
AS-i Outputs, DO 0 … DO 3 | No Function |
AS-i Parameter bits, P0 | Channel 2 switched |
AS-i Parameter bits, P1 ... P3 | No function |
Note (AS-i Parameter bits) | Set the parameter outputs to '1111' (0xF) FID: periphery error |
AS-i Input module address | 0 |
Note (AS-i Input module address) | Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |