- Universal coding with RFID technology
- 1 x connector socket M12, 8-pole
- Actuation from side
- Max. 31 sensors can be wired in series.
- serial diagnostic output
- Thermoplastic enclosure
- RFID-technology for needs-based protection against tampering
- Misaligned actuation possible
- 27 mm x 108.2 mm x 35 mm
- High repeat accuracy of the switching points
- 2 short-circuit proof PNP safety outputs
- Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
Ordering data
Product type description | RSS 36-SD-R-ST |
Article number (order number) | 101217290 |
EAN (European Article Number) | 4030661413419 |
eCl@ss number, Version 9.0 | 27-27-24-03 |
eCl@ss number, Version 11.0 | 27-27-24-03 |
Approval - Standards
Certificates | TÜV cULus ECOLAB EAC FCC IC |
General data
Standards | IEC 60947-5-3 |
general information | Universal coding |
Coding level according to ISO 14119 | Low |
Active principle | RFID |
Housing construction form | Block |
Installation conditions (mechanical) | not flush |
Sensor topology | Sensor for series wiring |
Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Active area | Glass-fibre, reinforced thermoplastic |
Gross weight | 100 g |
Time to readiness, maximum | 2,000 ms |
Reaction time, maximum | 100 ms |
Duration of risk, maximum | 200 ms |
General data - Features
Serial diagnostics | Yes |
Latching | Yes |
Diagnostic output | Yes |
Short circuit detection | Yes |
Short-circuit recognition | Yes |
Safety functions | Yes |
Cascadable | Yes |
Integral System Diagnostics, status | Yes |
Number of LEDs | 3 |
Number of semi-conductor outputs with signaling function | 1 |
Number of fail-safe digital outputs | 2 |
Number of Series-wiring of sensors | 31 |
Safety appraisal
Standards | EN ISO 13849-1 IEC 60947-5-3 EN 62061 IEC 61508 | |
Performance level, up to | e | |
Control category to EN13849 | 4 | |
PFH-value | 2.70 x 10⁻¹⁰ /h | |
| 3 | |
Mission Time | 20 Year(s) |
Mechanical data
Actuating panels | lateral |
Active area | lateral |
Hysteresis (Switch distance), maximum | 2 mm |
Repeat accuracy R R | 0.5 mm |
Note (Repeat accuracy R) | Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle). Minimum clearance between two sensor systems 100 mm. |
Latching force | 18 N |
Mounting | A screw length of 25 mm is sufficient for sensor mounting and for side mounting of the actuators. 30 mm long screws are recommended when the actuator is mounted upright and/or when the sealing discs are used. |
Mechanical data - Switching distances according IEC 60947-5-3
Switch distance | 12 mm |
Ensured switch distance ON Sao | 10 mm |
Ensured switch distance OFF Sar | 20 mm |
Mechanical data - Connection technique
Terminal Connector | Connector M12, 8-pole |
Note | The cable section of the interconnecting cable must be observed! Cable length and cable section alter the voltage drop depending on the output current |
Mechanical data - Dimensions
Length of sensor | 22 mm |
Width of sensor | 106.3 mm |
Height of sensor | 25 mm |
Ambient conditions
Degree of protection | IP65 to EN 60529 IP67 to EN 60529 IP69 to EN 60529 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +70 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +85 °C |
Material temperature resistance of the cable (in motion), minimum | -10 °C |
Material temperature resistance of the cable (at rest), minimum | -30 °C |
Material temperature resistance (long-term), maximum | +105 °C |
Resistance to vibrations to EN 60068-2-6 | 10 … 55 Hz, amplitude 1 mm |
Restistance to shock | 30 g / 11 ms |
Protection rating | III |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution to VDE 0100 | 3 |
Electrical data
Voltage type | DC (direct current) |
No-load supply current I0 | 100 mA |
Rated operating voltage | 24 VDC −15 % / +10 % |
Rated operating voltage, minimum | 20.4 VDC |
Rated operating voltage, maximum | 26.4 VDC |
Operating current | 600 mA |
Required rated short-circuit current to EN 60947-5-1 | 100 A |
Switching frequency, approx. | 1 Hz |
Electrical data - Fail-safe digital outputs
Rated operating current (safety outputs) | 250 mA |
Output current, (fail-safe output), maximum | 0.25 A |
Versions | p-type |
Voltage drop Ud, maximum | 1 V |
Current leakage Ir | 0.5 mA |
Voltage, Utilisation category DC12 | 24 VDC |
Current, Utilisation category DC12 | 0.25 A |
Voltage, Utilisation category DC13 | 24 VDC |
Current, Utilisation category DC13 | 0.25 A |
Electrical data - Diagnostic output
Operating current | 150 mA |
Versions | p-type |
Voltage drop Ud, maximum | 2 V |
Electrical data - Electromagnetic compatibility (EMC)
Interfering radiation | IEC 61000-6-4 |
EMC rating | IEC 60947-3 |
Status indication
Note (LED switching conditions display) | LED yellow: Operating condition LED green: Supply voltage LED red: Fault |
Pin assignment
PIN 1 | A1 Ue Brown |
PIN 2 | X1 Safety input 1 White |
PIN 3 | A2 GND Blue |
PIN 4 | Y1 Safety output 1 Black |
PIN 5 | serial diagnostic output OUT Grey |
PIN 6 | X2 Safety input 2 violet |
PIN 7 | Y2 Safety output 2 red |
PIN 8 | IN serial diagnostic input Pink |
Scope of delivery
Included in delivery | Actuators must be ordered separately. |
Accessory
Recommendation (actuator) | RST 36-1 RST 36-1-R |
Recommended safety switchgear | PROTECT PSC1 SRB-E-301ST SRB-E-201LC |
Notes
Note (General) | Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 2 ms. Short-circuit recognition by the evaluation is not necessary. |