- Guard locking monitored
- Thermoplastic enclosure
- Electronic contact-free, coded system
- Max. length of the sensor chain 200 m
- 3 LEDs to show operating conditions
- Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
- Intelligent diagnosis
- Manual release
Ordering data
Note (Delivery capacity) | Phased-out product |
Product type description | AZM 200 D ST2-T-1P2P2P |
Article number (order number) | 101217604 |
EAN (European Article Number) | 4030661412917 |
eCl@ss number, Version 9.0 | 27-27-26-03 |
eCl@ss number, Version 11.0 | 27-27-26-03 |
Available until | 31.12.2020 |
Approval - Standards
Certificates | TÜV cULus EAC |
General data
Standards | IEC 61508 IEC 60947-5-3 EN 60947-5-1 EN ISO 13849-1 |
Active principle | inductive |
Enclosure material | Glass-fibre, reinforced thermoplastic |
Gross weight | 600 g |
Time to readiness, maximum | 4,000 ms |
Reaction time, maximum | 60 ms |
Duration of risk, maximum | 120 ms |
General data - Features
Power to unlock | Yes |
Actuator monitored | Yes |
Guard locking monitored | Yes |
Manual release | Yes |
Short circuit detection | Yes |
Short-circuit recognition | Yes |
Safety functions | Yes |
Integral System Diagnostics, status | Yes |
Number of safety contacts | 4 |
Safety appraisal
Standards | IEC 60947-5-3 IEC 61508 |
Safety appraisal - Interlocking
Performance level, up to | e |
Control category | 4 |
PFH-value | 4.00 x 10⁻⁹ /h |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission Time | 20 Year(s) |
Safety appraisal - Interlocking 2
Performance Level, up to | d |
Control category | 3 |
PFH-value | 1.00 x 10⁻⁷ /h |
Safety Integrity Level (SIL), suitable for applications in | 2 |
Mission time | 20 Year(s) |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Clamping force in accordance with ISO14119 Fzh | 2,000 N |
Clamping force, maximum Fmax | 2,600 N |
Latching force | 30 N |
Actuating speed, maximum | 0.2 m/s |
Mechanical data - Connection technique
Terminal Connector | Connector M12, 8-pole |
Wire cross-section, minimum | 23 AWG |
Wire cross-section, maximum | 15 AWG |
Mechanical data - Dimensions
Length of sensor | 50 mm |
Width of sensor | 40 mm |
Height of sensor | 220 mm |
Ambient conditions
Degree of protection | IP67 to EN 60529 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +60 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +85 °C |
Resistance to vibrations to EN 60068-2-6 | 10 … 55 Hz, amplitude 1 mm |
Restistance to shock | 30 g / 11 ms |
Protection rating | II |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution to VDE 0100 | 3 |
Electrical data
Operating voltage, minimum | 20.4 VDC |
Operating voltage, maximum | 26.4 VDC |
No-load supply current I0 | 50 mA |
Operating current | 1,200 mA |
Note | Cable length and cable section alter the voltage drop depending on the output current |
Length of cable, maximum | 200 m |
Switching frequency, approx. | 1 Hz |
Electrical data - Solenoid control
Switching thresholds | -3 V … 5 V (Low) 15 V … 30 V (High) |
Classification ZVEI CB24I, Sink | C0 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Electrical data - Fail-safe digital inputs
Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
Electrical data - Fail-safe digital outputs
Voltage drop Ud, maximum | 4 V |
Current leakage Ir | 0.5 mA |
Voltage, Utilisation category DC13 | 24 VDC |
Current, Utilisation category DC13 | 0.25 A |
Note, Utilisation category DC13 | Gilt für die Ausgänge Y1 und Y2 |
Classification ZVEI CB24I, Source | C1 |
Classification ZVEI CB24I, Sink | C1 |
Electrical data - Diagnostic output
Operating current | 100 mA |
Voltage drop Ud, maximum | 4 V |
Voltage, Utilisation category DC13 | 24 VDC |
Current, Utilisation category DC13 | 0.05 A |
Status indication
Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage UB: LED green |
Pin assignment
PIN 1 | A1 Supply voltage UB |
PIN 2 | ELEC_DATA_CONNECTOR_1_PIN_ASSIGNMENT_2OUT |
PIN 3 | A2 GND |
PIN 4 | Y1 Safety output 1 |
PIN 5 | ELEC_DATA_CONNECTOR_1_PIN_ASSIGNMENT_5Y3 |
PIN 6 | ELEC_DATA_CONNECTOR_1_PIN_ASSIGNMENT_6Y4 |
PIN 7 | Y2 Safety output 2 |
PIN 8 | IN Solenoid control |
Scope of delivery
Included in delivery | Actuators must be ordered separately. Triangular key for AZM 200 |
Accessory
Recommendation (actuator) | AZ/AZM 200-B1 |
Notes
Note (General) | As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened. |
Note (Actuator monitored) | Safety outputs Y1, Y2 |
Note (Guard locking monitored) | Safety outputs Y3, Y4 |