- Universal coding with RFID technology
- Connector M12, 8-pole
- Power to unlock
- Actuator monitored
- serial diagnostic output
- Hygienic design
- Protection class IP 69
- Suitable for mounting to profile systems
- Thermoplastic enclosure
- RFID-technology for needs-based protection against tampering
- 3 different directions of actuation
- Compact design
- 3 LEDs to show operating conditions
- Suitable for hinged and sliding guards
- Series-wiring
- Manual release
Ordering data
Product type description | AZM300B-ST-SD2P |
Article number (order number) | 103001412 |
EAN (European Article Number) | 4030661425955 |
eCl@ss number, Version 9.0 | 27-27-26-03 |
eCl@ss number, Version 11.0 | 27-27-26-03 |
Approval - Standards
Certificates | TÜV cULus ECOLAB EAC FCC IC |
General data
Standards | IEC 61508 IEC 60947-5-3 EN ISO 13849-1 EN ISO 14119 | |
general information | Universal coding | |
Coding level according to ISO 14119 | Low | |
Active principle | RFID | |
Frequency band RFID | 125 kHz | |
Transmit power, maximum | -6 dB/m | |
Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing | |
Gross weight | 550 g | |
Time to readiness, maximum | 5,000 ms | |
Duration of risk, maximum | 200 ms | |
| 100 ms | |
| 1.5 ms | |
CODE_CODING_LEVEL_ISO14119_GEN | CODE_CODING_LEVEL_ISO14119_GEN1000078521 | |
DIM_ANGLE_ACTIVE_PRINCIPLE_GEN | RFID |
General data - Features
Power to unlock | Yes |
Actuator monitored | Yes |
Serial diagnostics | Yes |
Latching | Yes |
Manual release | Yes |
Short circuit detection | Yes |
Short-circuit recognition | Yes |
Series-wiring | Yes |
Safety functions | Yes |
Integral System Diagnostics, status | Yes |
Number of fail-safe digital outputs | 2 |
Safety appraisal
Standards | EN ISO 13849-1 IEC 61508 |
Safety appraisal - Interlocking
Performance level, up to | e |
Control category | 4 |
PFH-value | 5.20 x 10⁻¹⁰ /h |
PFD value | 4.50 x 10⁻⁵ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission Time | 20 Year(s) |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Note (Mechanical lifetime) | When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s) |
Angular offset between interlocking device and actuator, maximum | 2 ° |
Clamping force in accordance with ISO14119 Fzh | 1,150 N |
Clamping force, maximum Fmax | 1,500 N |
Latching force, adjustable, position 1 | 25 N |
Latching force, adjustable, position 2 | 50 N |
Type of the fixing screws | 2x M6 |
Tightening torque of the fixing screws, minimum | 6 Nm |
Tightening torque for the fixing screws, maximum | 7 Nm |
ELEC_DATA_SWITCHING_THRESHOLDS_S_GEN | −3 V … 5 V (Low) |
VOLTAGE_OPERATION_DC_MAX_GEN | 26.4 |
VOLTAGE_OPERATION_DC_MIN_GEN | 20.4 |
Mechanical data - Switching distances according IEC 60947-5-3
Switch distance | 2 mm |
Ensured switch distance ON Sao | 1 mm |
Ensured switch distance OFF Sar | 20 mm |
Mechanical data - Connection technique
Terminal Connector | Connector M12, 8-pole, A-coded |
Length of sensor chain, maximum | 200 m |
Note (length of the sensor chain) | Cable length and cross-section change the voltage drop dependiing on the output current |
Note (series connection of the sensors) | Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD |
Mechanical data - Dimensions
Length of sensor | 120 mm |
Width of sensor | 87.5 mm |
Height of sensor | 35 mm |
Ambient conditions
Degree of protection | IP66 to EN 60529 IP67 to EN 60529 IP69 to EN 60529 |
Ambient temperature, minimum | +0 °C |
Ambient temperature, maximum | +60 °C |
Storage and transport temperature, minimum | -10 °C |
Storage and transport temperature, maximum | +90 °C |
Relative humidity, maximum | 93 % |
Note (Relative humidity) | non-condensing non-icing |
Resistance to vibrations to EN 60068-2-6 | 10 … 150 Hz, amplitude 0.35 mm |
Restistance to shock | 30 g / 11 ms |
Protection rating | III |
Zulässige Aufstellhöhe über NN, maximum | 2,000 m |
TEMP_STORAGE_AND_TRANSPORT_MAX_GEN | +90 |
TEMP_STORAGE_AND_TRANSPORT_MIN_GEN | -10 |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution to IEC/EN 60664-1 | 3 |
Electrical data
Operating voltage, minimum | 20.4 VDC |
Operating voltage, maximum | 26.4 VDC |
Notes (Power supply, general) | stabilised PELV power supply |
No-load supply current I0 | 100 mA |
Current consumption with solenoid ON, average | 200 mA |
Current consumption with solenoid ON, peak | 350 mA / 200 ms |
Required rated short-circuit current to EN 60947-5-1 | 100 A |
External wiring and device fuse rating | 2 A gG |
Switching frequency, maximum | 0.5 Hz |
Electrical data - Solenoid control
Switching thresholds | -3 V … 5 V (Low) 15 V … 30 V (High) |
Duty cycle solenoid | 100 % |
Test pulse duration, maximum | 5 ms |
Test pulse interval, minimum | 40 ms |
Classification ZVEI CB24I, Sink | C0 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Electrical data - Fail-safe digital inputs
Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24V | 5 mA |
Test pulse duration, maximum | 1 ms |
Test pulse interval, minimum | 100 ms |
Classification ZVEI CB24I, Sink | C1 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Electrical data - Fail-safe digital outputs
Versions | short-circuit proof, p-type |
Voltage drop Ud, maximum | 4 V |
Current leakage Ir | 0.5 mA |
Voltage, Utilisation category DC12 | 24 VDC |
Current, Utilisation category DC12 | 0.25 A |
Voltage, Utilisation category DC13 | 24 VDC |
Current, Utilisation category DC13 | 0.25 A |
Test pulse duration, maximum | 0.5 ms |
Test pulse interval, typical | 1000 ms |
Classification ZVEI CB24I, Source | C2 |
Classification ZVEI CB24I, Sink | C1 C2 |
Electrical data - Diagnostic output
Versions | short-circuit proof, p-type |
Voltage drop Ud, maximum | 4 V |
Voltage, Utilisation category DC12 | 24 VDC |
Current, Utilisation category DC12 | 0.05 A |
Voltage, Utilisation category DC13 | 24 VDC |
Current, Utilisation category DC13 | 0.05 A |
Electrical data - Serial diagnostic SD
Operation current | 150 mA |
Wiring capacity | 50 nF |
Status indication
Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage UB: LED green |
Pin assignment
PIN 1 | A1 Supply voltage UB |
PIN 2 | X1 Safety input 1 |
PIN 3 | A2 GND |
PIN 4 | Y1 Safety output 1 |
PIN 5 | OUT serial diagnostic output |
PIN 6 | X2 Safety input 2 |
PIN 7 | Y2 Safety output 2 |
PIN 8 | IN serial diagnostic input |