  • Repeated individual coding with RFID technology
  • Coding level 'High' according to ISO 14119
  • Connector M12, 8-pole
  • Power to lock
  • Actuator monitored
  • serial diagnostic output
  • Hygienic design
  • Protection class IP 69
  • Suitable for mounting to profile systems
  • Thermoplastic enclosure
  • RFID-technology for needs-based protection against tampering
  • 3 different directions of actuation
  • Compact design
  • 3 LEDs to show operating conditions
  • Suitable for hinged and sliding guards
  • Series-wiring
  • Manual release

Ordering data

Product type description

AZM300B-I2-ST-SD2P-A

Article number (order number)

103001428

EAN (European Article Number)

4030661425870

eCl@ss number, Version 9.0

27-27-26-03

eCl@ss number, Version 11.0

27-27-26-03

Approval - Standards

Certificates

TÜV

cULus

ECOLAB

EAC

FCC

IC

General data

Standards

IEC 61508

IEC 60947-5-3

EN ISO 13849-1

EN ISO 14119

general information

Individual coding, multiple teaching

Coding level according to ISO 14119

High

Active principle

RFID

Frequency band RFID

125 kHz

Transmit power, maximum

-6 dB/m

Enclosure material

Plastic, glass-fibre reinforced thermoplastic, self-extinguishing

Gross weight

610 g

Time to readiness, maximum

5,000 ms

Duration of risk, maximum

200 ms

Response time safety outputs in case of switch-off by actuator, maximum

100 ms

Response time safety outputs in case of switch-off by safety inputs, maximum

1.5 ms

CODE_CODING_LEVEL_ISO14119_GEN

CODE_CODING_LEVEL_ISO14119_GEN1000078521

DIM_ANGLE_ACTIVE_PRINCIPLE_GEN

RFID

General data - Features

Power to lock

Yes

Actuator monitored

Yes

Serial diagnostics

Yes

Latching

Yes

Manual release

Yes

Short circuit detection

Yes

Short-circuit recognition

Yes

Series-wiring

Yes

Safety functions

Yes

Integral System Diagnostics, status

Yes

Number of fail-safe digital outputs

2

Safety appraisal

Standards

EN ISO 13849-1

IEC 61508

Safety appraisal - Interlocking

Performance level, up to

e

Control category

4

PFH-value

5.20 x 10⁻¹⁰ /h

PFD value

4.50 x 10⁻⁵

Safety Integrity Level (SIL), suitable for applications in

3

Mission Time

20 Year(s)

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Note (Mechanical lifetime)

When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s)

Angular offset between interlocking device and actuator, maximum

2 °

Clamping force in accordance with ISO14119 Fzh

1,150 N

Clamping force, maximum Fmax

1,500 N

Latching force, adjustable, position 1

25 N

Latching force, adjustable, position 2

50 N

Type of the fixing screws

2x M6

Tightening torque of the fixing screws, minimum

6 Nm

Tightening torque for the fixing screws, maximum

7 Nm

ELEC_DATA_SWITCHING_THRESHOLDS_S_GEN

−3 V … 5 V (Low)

15 V … 30 V (High)

VOLTAGE_OPERATION_DC_MAX_GEN

26.4

VOLTAGE_OPERATION_DC_MIN_GEN

20.4

Mechanical data - Switching distances according IEC 60947-5-3

Switch distance

2 mm

Ensured switch distance ON Sao

1 mm

Ensured switch distance OFF Sar

20 mm

Mechanical data - Connection technique

Terminal Connector

Connector M12, 8-pole, A-coded

Length of sensor chain, maximum

200 m

Note (length of the sensor chain)

Cable length and cross-section change the voltage drop dependiing on the output current

Note (series connection of the sensors)

Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD

Mechanical data - Dimensions

Length of sensor

120 mm

Width of sensor

87.5 mm

Height of sensor

35 mm

Ambient conditions

Degree of protection

IP66 to EN 60529

IP67 to EN 60529

IP69 to EN 60529

Ambient temperature, minimum

+0 °C

Ambient temperature, maximum

+60 °C

Storage and transport temperature, minimum

-10 °C

Storage and transport temperature, maximum

+90 °C

Relative humidity, maximum

93 %

Note (Relative humidity)

non-condensing

non-icing

Resistance to vibrations to EN 60068-2-6

10 … 150 Hz, amplitude 0.35 mm

Restistance to shock

30 g / 11 ms

Protection rating

III

Zulässige Aufstellhöhe über NN, maximum

2,000 m

TEMP_STORAGE_AND_TRANSPORT_MAX_GEN

+90

TEMP_STORAGE_AND_TRANSPORT_MIN_GEN

-10

Ambient conditions - Insulation value

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution to IEC/EN 60664-1

3

Electrical data

Operating voltage, minimum

20.4 VDC

Operating voltage, maximum

26.4 VDC

Notes (Power supply, general)

stabilised PELV power supply

No-load supply current I0

100 mA

Current consumption with solenoid ON, average

200 mA

Current consumption with solenoid ON, peak

350 mA / 200 ms

Required rated short-circuit current to EN 60947-5-1

100 A

External wiring and device fuse rating

2 A gG

Switching frequency, maximum

0.5 Hz

Electrical data - Solenoid control

Switching thresholds

-3 V … 5 V (Low)

15 V … 30 V (High)

Duty cycle solenoid

100 %

Test pulse duration, maximum

5 ms

Test pulse interval, minimum

40 ms

Classification ZVEI CB24I, Sink

C0

Classification ZVEI CB24I, Source

C1

C2

C3

Electrical data - Fail-safe digital inputs

Switching thresholds

−3 V … 5 V (Low)

15 V … 30 V (High)

Current consumption at 24V

5 mA

Test pulse duration, maximum

1 ms

Test pulse interval, minimum

100 ms

Classification ZVEI CB24I, Sink

C1

Classification ZVEI CB24I, Source

C1

C2

C3

Electrical data - Fail-safe digital outputs

Versions

short-circuit proof, p-type

Voltage drop Ud, maximum

4 V

Current leakage Ir

0.5 mA

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

0.25 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

0.25 A

Test pulse duration, maximum

0.5 ms

Test pulse interval, typical

1000 ms

Classification ZVEI CB24I, Source

C2

Classification ZVEI CB24I, Sink

C1

C2

Electrical data - Diagnostic output

Versions

short-circuit proof, p-type

Voltage drop Ud, maximum

4 V

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

0.05 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

0.05 A

Electrical data - Serial diagnostic SD

Operation current

150 mA

Wiring capacity

50 nF

Status indication

Note (LED switching conditions display)

Operating condition: LED green

Error / functional defect: LED red

Supply voltage UB: LED green

Pin assignment

PIN 1

A1 Supply voltage UB

PIN 2

X1 Safety input 1

PIN 3

A2 GND

PIN 4

Y1 Safety output 1

PIN 5

OUT serial diagnostic output

PIN 6

X2 Safety input 2

PIN 7

Y2 Safety output 2

PIN 8

IN serial diagnostic input