- Individual coding with RFID technology
- Coding level 'High' according to ISO 14119
- 1 x connector plug M8
- Frontal and lateral actuation enabled
- Max. 31 sensors can be wired in series.
- Thermoplastic enclosure
- Simple mounting without additional angle
- RFID-technology for needs-based protection against tampering
Ordering data
Product type description | RSS260-I1-SD-ST |
Article number (order number) | 103003604 |
EAN (European Article Number) | 4030661436456 |
eCl@ss number, Version 9.0 | 27-27-24-03 |
eCl@ss number, Version 11.0 | 27-27-24-03 |
Approval - Standards
Certificates | TÜV cULus EAC FCC IC |
General data
Standards | IEC 60947-5-3 |
general information | Individual coding |
Coding level according to ISO 14119 | High |
Active principle | RFID |
Housing construction form | Block |
Installation conditions (mechanical) | not flush |
Sensor topology | Sensor for series wiring |
Enclosure material | Plastic, thermoplastic, self-extinguishing |
Active area | Glass-fibre, thermoplastic |
Gross weight | 54 g |
Time to readiness, maximum | 2,000 ms |
Reaction time, maximum | 100 ms |
Duration of risk, maximum | 200 ms |
General data - Features
Serial diagnostics | Yes |
Diagnostic output | Yes |
Short circuit detection | Yes |
Short-circuit recognition | Yes |
Safety functions | Yes |
Cascadable | Yes |
Integral System Diagnostics, status | Yes |
Number of LEDs | 3 |
Number of semi-conductor outputs with signaling function | 1 |
Number of fail-safe digital outputs | 2 |
Number of Series-wiring of sensors | 31 |
Safety appraisal
Standards | EN ISO 13849-1 IEC 60947-5-3 EN 62061 IEC 61508 | |
Performance level, up to | e | |
Control category to EN13849 | 4 | |
PFH-value | 6.80 x 10⁻¹⁰ /h | |
| 3 | |
Mission Time | 20 Year(s) |
Mechanical data
Actuating panels | lateral front side |
Active area | lateral front |
Hysteresis (Switch distance), maximum | 2 mm |
Repeat accuracy R R | 0.5 mm |
Note (Repeat accuracy R) | Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle). Minimum clearance between two sensor systems 100 mm |
Mounting | A 20 mm screw length usually suffices to mount the sensor. When the mounting plates are used, we recommend 25 mm long screws. |
Mechanical data - Switching distances according IEC 60947-5-3
Switch distance Sn | front 12 mm lateral 9 mm |
Ensured switching distance ON, front | 10 mm |
Ensured switching distance OFF, front | 18 mm |
Ensured switching distance ON, side | 6 mm |
Ensured switch distance OFF Sar, lateral | 15 mm |
Mechanical data - Connection technique
Terminal Connector | Connector M8 |
Note | The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current |
Mechanical data - Dimensions
Length of sensor | 29.5 mm |
Width of sensor | 39.2 mm |
Height of sensor | 18 mm |
Ambient conditions
Degree of protection | IP65 to EN 60529 IP67 to EN 60529 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +65 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +85 °C |
Resistance to vibrations to EN 60068-2-6 | 10 … 55 Hz, amplitude 1 mm |
Restistance to shock | 30 g / 11 ms |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution to VDE 0100 | 3 |
Electrical data
Voltage type | DC (direct current) |
No-load supply current I0 | 100 mA |
Rated operating voltage | 24 VDC -15% / +10% |
Rated operating voltage, minimum | 20.4 VDC |
Rated operating voltage, maximum | 26.4 VDC |
Operating current | 600 mA |
Required rated short-circuit current to EN 60947-5-1 | 100 A |
Switching frequency, approx. | 1 Hz |
Electrical data - Fail-safe digital outputs
Versions | p-type |
Voltage drop Ud, maximum | 1 V |
Current leakage Ir | 0.5 mA |
Voltage, Utilisation category DC12 | 24 VDC |
Current, Utilisation category DC12 | 0.25 A |
Voltage, Utilisation category DC13 | 24 VDC |
Current, Utilisation category DC13 | 0.25 A |
Electrical data - Diagnostic output
Operating current | 150 mA |
Versions | p-type |
Voltage drop Ud, maximum | 2 V |
Electrical data - Electromagnetic compatibility (EMC)
Interfering radiation | IEC 61000-6-4 |
EMC rating | IEC 60947-3 |
Status indication
Note (LED switching conditions display) | LED yellow: Operating condition LED green: Supply voltage LED red: Fault |
Pin assignment
PIN 1 | A1 Ue: White |
PIN 2 | X1 safety input 1: Brown |
PIN 3 | A2 GND: Green |
PIN 4 | Y1 safety output 1: Yellow |
PIN 5 | serial diagnostic output OUT Grey |
PIN 6 | X2 safety input 2: Pink |
PIN 7 | Y2 safety output 2: Blue |
PIN 8 | IN serial diagnostic input Pink |
Accessory
Recommendation (actuator) | RST16-1 RST-U-2 RST260-1 |
Recommended safety switchgear | PROTECT PSC1 SRB-E-301ST SRB-E-201LC |