- Single-conductor entry with strain relief
- Thermoplastic enclosure
- Contact pin in actuator bridge
- 1 Actuating planes
- Protection against accidental contact with additional wall
- transparent cover
- fixing screws M4 undetachable, captive
- Fitting dimensions suitable for AZ 06x
- Self-cleaning through the frictional mouvement of the contact bridges
- Protection class IP20
Ordering data
Product type description | AZ06KT |
Article number (order number) | 103003680 |
EAN (European Article Number) | 4030661429755 |
eCl@ss number, Version 9.0 | 27-27-06-10 |
eCl@ss number, Version 11.0 | 27-27-06-10 |
ETIM number, version 6.0 | EC002592 |
ETIM number, version 7.0 | EC002592 |
General data
Standards | EN 81-20 EN 81-50 |
Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Material of the contacts, electrical | Silver-plated Cu rivets |
Material of the cover | transparent thermoplastic |
Gross weight | 35.2 g |
General data - Features
Suitable for elevators | Yes |
Number of safety contacts | 1 |
Mechanical data
Actuating panels | 1 |
Mechanical life, minimum | 1,000,000 Operations |
Actuating stroke | 7 mm |
Actuating force, approx. | 1.6 N |
Mounting | Round holes |
Mechanical data - Connection technique
Terminal Connector | Screw connection |
Cable entry | Single-conductor entry with strain relief |
Mechanical data - Dimensions
Width | 72 mm |
Height | 22 mm |
Depth | 19 mm |
Ambient conditions
Degree of protection | IP20 |
Ambient temperature, minimum | -15 °C |
Ambient temperature, maximum | +70 °C |
Relative humidity, maximum | 95 % |
Note (Relative humidity) | non-condensing |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 500 V |
Electrical data
Thermal test current | 4 A |
Utilisation category AC-15 | 230 VAC |
Utilisation category AC-15 | 2 A |
Utilisation category DC-13 | 200 VDC |
Utilisation category DC-13 | 2 A |
Switching element | Opener (NC) |
Switching principle | Self-cleaning pressure contact |
Scope of delivery
Included in delivery | Actuators must be ordered separately. |
Notes
Note (General) | The connecting screws can be sealed with plugs. (2 plugs per switch) |