Бренды по алфавиту:
А Б В Г Д Е Ё Ж З И Й К Л М Н О П Р С Т У Ф Х Ц Ч Ш Щ Ъ Ы Ь Э Ю Я
Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Оплата по безналичному расчету согласно выставленному счету
Самовывоз - бесплатно, от 300руб. до пункта выдачи в Вашем городе, доставка от 500руб. "до двери"
  • Single-conductor entry with strain relief
  • Thermoplastic enclosure
  • Contact pin in actuator bridge
  • 1 Actuating planes
  • Protection against accidental contact with additional wall
  • transparent cover
  • fixing screws M4 undetachable, captive
  • Fitting dimensions suitable for AZ 06x
  • Self-cleaning through the frictional mouvement of the contact bridges
  • Protection class IP20

Ordering data

Product type description

AZ06KT

Article number (order number)

103003680

EAN (European Article Number)

4030661429755

eCl@ss number, Version 9.0

27-27-06-10

eCl@ss number, Version 11.0

27-27-06-10

ETIM number, version 6.0

EC002592

ETIM number, version 7.0

EC002592

General data

Standards

EN 81-20

EN 81-50

Enclosure material

Plastic, glass-fibre reinforced thermoplastic, self-extinguishing

Material of the contacts, electrical

Silver-plated Cu rivets

Material of the cover

transparent thermoplastic

Gross weight

35.2 g

General data - Features

Suitable for elevators

Yes

Number of safety contacts

1

Mechanical data

Actuating panels

1

Mechanical life, minimum

1,000,000 Operations

Actuating stroke

7 mm

Actuating force, approx.

1.6 N

Mounting

Round holes

Mechanical data - Connection technique

Terminal Connector

Screw connection

Cable entry

Single-conductor entry with strain relief

Mechanical data - Dimensions

Width

72 mm

Height

22 mm

Depth

19 mm

Ambient conditions

Degree of protection

IP20

Ambient temperature, minimum

-15 °C

Ambient temperature, maximum

+70 °C

Relative humidity, maximum

95 %

Note (Relative humidity)

non-condensing

Ambient conditions - Insulation value

Rated insulation voltage Ui

500 V

Electrical data

Thermal test current

4 A

Utilisation category AC-15

230 VAC

Utilisation category AC-15

2 A

Utilisation category DC-13

200 VDC

Utilisation category DC-13

2 A

Switching element

Opener (NC)

Switching principle

Self-cleaning pressure contact

Scope of delivery

Included in delivery

Actuators must be ordered separately.

Notes

Note (General)

The connecting screws can be sealed with plugs. (2 plugs per switch)

Наш менеджер свяжется с вами в ближайшее время