- Compact Safety-Input module
- Integrated in the passive junction
- for 2 potential-free NC contacts
- Protection class IP67
Ordering data
Product type description | ASIM-C-M12-4P-2M |
Article number (order number) | 103004695 |
EAN (European Article Number) | 4030661441054 |
eCl@ss number, Version 9.0 | 27-24-26-04 |
eCl@ss number, Version 11.0 | 27-24-26-04 |
ETIM number, version 6.0 | EC001599 |
Approval - Standards
Certificates | TÜV cULus |
General data
Standards | EN 50295 EN 60204-1 EN 62061 EN ISO 13849-1 |
Enclosure material | Thermoplastic PBT |
Gross weight | 137 g |
Reaction time, maximum | 1 ms |
Duration of risk, maximum | 5 ms |
General data - Features
Safety functions | Yes |
Integral System Diagnostics, status | Yes |
Safety appraisal
Standards | EN 62061 | |
Performance level, up to | e | |
Control category to EN13849 | 4 | |
| 3 | |
Mission Time | 20 Year(s) |
Mechanical data - Connection technique
Terminal Connector | Connector, M12, 4-pole, A-coded |
Length of cable | 2 m |
Material of the cable | Polyurethane PUR |
Mechanical data - Dimensions
Width | 27.7 mm |
Height | 40.5 mm |
Depth | 22 mm |
Ambient conditions
Degree of protection | IP67 to EN 60529 |
Ambient temperature, minimum | -20 °C |
Ambient temperature, maximum | +60 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +80 °C |
Relative humidity, minimum | 30 % |
Relative humidity, maximum | 95 % |
Note (Relative humidity) | non-condensing non-icing |
Resistance to vibrations to EN 60068-2-6 | 10 … 57 Hz, amplitude 0.75 mm |
Restistance to shock | 30 g / 11 ms |
Protection rating | III |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution to VDE 0100 | 3 |
Electrical data - AS Interface
AS-i Operating voltage, minimum | 26.5 VDC |
AS-i Operating voltage AS-i maximum | 31.6 VDC |
Note (AS-i Operating voltage) | Protection against polarity reversal |
AS-i Current consumption, maximum | 90 mA |
Electrical data - AS-Interface specification
AS-i Version | V 3.0 |
AS-i Profile | S-0.B.F.0 |
AS-i Input, Channel 1 | Data bits DI 0 / DI 1 = dynamic code transmission |
AS-i Input, Channel 2 | Data bits DI 2 / DI 3 = dynamic code transmission |
AS-i Outputs, DO 0 | No Function |
AS-i Outputs, DO 1 … DO 3 | No Function |
AS-i Parameter bits, P0 | Communication monitoring AS-i |
AS-i Parameter bits, P1 ... P3 | No function |
Note (AS-i Parameter bits) | Set the parameter outputs to '1111' (0xF) |
AS-i Input module address | 0 |
Note (AS-i Input module address) | Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |
Status indication